beautypg.com

Teccor, Brand thyristors, 1 amp sensitive & standard triacs – Littelfuse QxNx Series User Manual

Page 6

background image

40

Revised: 09/23/13

©2013 Littelfuse, Inc

Specifications are subject to change without notice.

Teccor

®

brand Thyristors

1 Amp Sensitive & Standard Triacs

Lx01Ex & LxNx & Qx01Ex & QxNx Series

Environmental Specifications

Test

Specifications and Conditions

AC Blocking

MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours

Temperature Cycling

MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell time

Temperature/
Humidity

EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity

High Temp Storage

MIL-STD-750, M-1031,
1008 hours; 150°C

Low-Temp Storage

1008 hours; -40°C

Thermal Shock

MIL-STD-750, M-1056
10 cycles; 0°C to 100°C; 5-min dwell
time at each temperature; 10 sec (max)
transfer time between temperature

Autoclave

EIA / JEDEC, JESD22-A102
168 hours (121°C at 2 ATMs) and
100% R/H

Resistance to
Solder Heat

MIL-STD-750 Method 2031

Solderability

ANSI/J-STD-002, category 3, Test A

Lead Bend

MIL-STD-750, M-2036 Cond E

Physical Specifications

Terminal Finish

100% Matte Tin-plated

Body Material

UL recognized epoxy meeting flammability
classification 94V-0

Terminal Material

Copper Alloy

Dimensions - Compak (C Package)

Dimension

Inches

Millimeters

Min

Max

Min

Max

A

0.130

0.156

3.30

3.95

B

0.201

0.220

5.10

5.60

C

0.077

0.087

1.95

2.20

D

0.159

0.181

4.05

4.60

E

0.030

0.063

0.75

1.60

F

0.075

0.096

1.90

2.45

G

0.002

0.008

0.05

0.20

H

0.077

0.104

1.95

2.65

J

0.043

0.053

1.09

1.35

K

0.006

0.016

0.15

0.41

L

0.030

0.055

0.76

1.40

M

0.022

0.028

0.56

0.71

N

0.027

0.033

0.69

0.84

P

0.052

0.058

1.32

1.47

0.079

(2.0)

0.040

(1.0)

0.030
(0.76)

0.079

(2.0)

0.079

(2.0)

0.110

(2.8)

Pad Outline

H

K

J

E

F

L

G

A

C

B

M

D

N

P

Gate

MT1

MT2

T

C

/ T

L

Temperature

Measurement Point

Dimensions are in inches
(and millimeters).

Design Considerations

Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of the Thyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.