Littelfuse QxNx Series User Manual
Lx01ex & lxnx & qx01ex & qxnx series, Teccor, Brand thyristors

35
Revised: 09/23/13
©2013 Littelfuse, Inc
Specifications are subject to change without notice.
Teccor
®
brand Thyristors
1 Amp Sensitive & Standard Triacs
Lx01Ex & LxNx & Qx01Ex & QxNx Series
Lx01Ex & LxNx & Qx01Ex & QxNx Series
Description
1 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Sensitive type devices guarantee gate control in Quadrants
I & IV needed for digital control circuitry.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Main Features
Symbol
Value
Unit
I
T(RMS)
1
A
V
DRM
/ V
RRM
400 to 600
V
I
GT (Q1)
3 to 25
mA
Features & Benefits
Schematic Symbol
Applications
Excellent for lower current heating controls, water valves,
and solenoids.
Typical applications are AC solid-state switches, home/
brown goods and white goods appliances.
Sensitive gate Triacs can be directly driven by
microprocessor or popular opto-couplers/isolators.
MT2
MT1
G
Absolute Maximum Ratings — Sensitive Triacs
(4 Quadrants)
Symbol
Parameter
Value
Unit
I
T(RMS)
RMS on-state current
(full sine wave)
Lx01Ey/LxNy
T
C
= 50°C
1
A
I
TSM
Non repetitive surge peak on-state current
(full cycle, T
J
initial = 25°C)
f = 50 Hz
t = 20 ms
16.7
A
f = 60 Hz
t = 16.7 ms
20
I
2
t
I
2
t Value for fusing
t
p
= 8.3 ms
1.6
A
2
s
di/dt
Critical rate of rise of on-state current
(I
G
= 50mA with
d 0.1μs rise time)
f = 120 Hz
T
J
= 110°C
20
A/μs
I
GTM
Peak gate trigger current
t
p
d 10 μs
T
J
= 110°C
1
A
P
G(AV)
Average gate power dissipation
T
J
= 110°C
0.2
W
T
stg
Storage temperature range
Lx01Ey
-65 to 150
°C
LxNy
-40 to 125
T
J
Operating junction temperature range
Lx01Ey
-65 to 110
°C
LxNy
-40 to 110
Note: x = voltage, y = sensitivity
t3P)4$PNQMJBOU
t(MBTToQBTTJWBUFE
junctions
t7PMUBHFDBQBCJMJUZVQUP
600 V
t4VSHFDBQBCJMJUZVQUP
20 A