beautypg.com

Teccor, Brand thyristors – Littelfuse Qxx16xHx Series User Manual

Page 4

background image

124

Revised: 09/23/13

©2013 Littelfuse, Inc

Specifications are subject to change without notice.

Teccor

®

brand Thyristors

15 Amp Standard & 16 Amp Alternistor (High Commutation) Triacs

Qxx15xx & Qxx16xHx Series

Figure 3: Normalized DC Holding Current

vs. Junction Temperature

+125

0.0

1.0

2.0

3.0

4.0

-65 -40 -15 10 35 60 85 100

Junction Temperature (T

J

) - ºC

Ratio of

I

IH

/ I

IH

(T

J

= 2

5

ºC)

Figure 4: Normalized DC Gate Trigger Voltage for

All Quadrants vs. Junction Temperature

+125

0.0

0.5

1.0

1.5

2.0

-65 -40 -15 10 35 60 85 100

Junction Temperature (T

J

) - ºC

Ratio of

V

GT

/ V

GT

(T

J

= 2

5

ºC)

0

2

4

6

8

10

12

14

16

18

RMS On-State Current [I

T(RMS)

] - AMPS

Average On-State Powe

r Dissi

pation

[P

D(AV)

] - Watts

0 2 4 6 8 10 12 14 16 18

Figure 5: Power Dissipation (Typical)

vs. RMS On-State Current

Figure 6: Maximum Allowable Case Temperature

vs. On-State Current (15A devices)

Qxx15L5

Qxx15R5
Qxx15N5

60

70

80

90

100

110

120

130

0 5 10 15

RMS On-State Current [I

T(RMS)

] - AMPS

Max Allowable Case Temperature (T

C

) - ºC

o

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
CASE TEMPERATURE: Measured as shown
on dimensional drawing

Figure 8: Maximum Allowable Ambient Temperature

vs. On-State Current

20

30

40

50

60

70

80

90

100

110

120

RMS On-State Current [I

T(RMS)

] - AMPS

Max Allowable Ambiant Temperatur

e

(T

A

) - ºC

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
CASE TEMPERATURE: Measured as shown
on dimensional drawing

Qxx15Ry
Qxx15L
Qxx16RHy
Qxx16LHy

Figure 7: Maximum Allowable Case Temperature

vs. On-State Current (16A devices)

Qxx16LHy

Qxx16RHy
Qxx16NHy

60

70

80

90

100

110

120

130

0 5 10 15 20

RMS On-State Current [I

T(RMS)

] - AMPS

Max Allowable Case Tem

p

er

atu

re

(T

C

) - ºC

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
CASE TEMPERATURE: Measured as shown
on dimensional drawing