beautypg.com

Transient voltage suppression diodes, Tvs diode arrays, Surface mount – 1500w > smcj-hra series – Littelfuse SMCJ-HRA Series User Manual

Page 3: Family of products), I-v curve characteristics, Figure 2 - peak pulse power rating, Screen process

background image

Transient Voltage Suppression Diodes

36

TVS Diode Arrays

(SPA

Family of Products)

©2013 Littelfuse, Inc.

Specifications are subject to change without notice.

Revised: 10/24/13

Surface Mount – 1500W > SMCJ-HRA series

SMCJ-HRA Series

I-V Curve Characteristics

Voltage Transients

Time

Voltage Across TVS

Current Through TVS

Voltage or Current

Figure 1 - TVS Transients Clamping Waveform

Ratings and Characteristic Curves

(T

A

=25°C unless otherwise noted)

1

10

100

0.000001

0.00001

0.0001

0.001

t

d

-Pulse Width (sec.)

P

PPM

-Peak Pulse Power (kW)

0.31x0.31" (8.0x8.0mm)
Copper Pad Area

Figure 2 - Peak Pulse Power Rating

Vc V

BR

V

R

I

R

I

T

I

pp

V

Uni-directional

V

F

Vc V

BR

V

R

I

R

I

T

I

pp

V

Vc

V

BR

V

R

I

pp

I

R

I

T

Bi-directional

P

PPM

Peak Pulse Power Dissipation -- Max power dissipation

V

R

Stand-off Voltage -- Maximum voltage that can be applied to the TVS without operation

V

BR

Breakdown Voltage -- Maximum current that flows though the TVS at a specified test current (I

T

)

V

C

Clamping Voltage -- Peak voltage measured across the suppressor at a specified Ippm (peak impulse current)

I

R

Reverse Leakage Current -- Current measured at V

R

V

F

Forward Voltage Drop for Uni-directional

continues on next page.

3

Screen Process

100% vision inspection

MIL-STD-750 method 2074

100%High Temperature Storage Life (168hrs,150C)

MIL-STD-750 method 1031

100% X-RAY inspection

MIL-STD-750 method 2076

100% Temperature cycle test (-55-150C, 20 cycles, dwell time 15 min)

MIL-STD-750 method 1051

100% Reflow (2X)

JEDEC J-STD-020

100% surge test (2x)

MIL-STD-750 method 4066

100% HTRB(150C, Bias=VR(80% breakdown voltage), 96hrs),for Bi-
direction products, 96hrs for each direction

MIL–STD–750 method 1038

Final electrical test( 100% 3 sigma limit, 100% dynamic test and PAT
limit)

MIL-STD-750 method 4016.4021.4011

Note: Up-screen program can be specified by customer’s request via contacting Littlefuse service