2 TECHNICAL
CHARACTERISTICS
m
CAUTION: Never exceed the maximum load capacity that is indicated on the rating plate on the
TMU unit.
2.1 Specification and Minimum Radius Curve – TMU Variable
Frequency Drive
Table 2. Specification and Minimum Radius Curve - TMU Variable Frequency Drive
Trolley Type and Drive
Motor Type
Min. Radius Curve
C2 + TMU VFD less gear
reducer
MF06MK200
6.56 ft [2m]
C2 + TMU VFD
MF06MK200
6.56 ft [2m]
C3 + TMU VFD
MF06MK200
6.56 ft [2m]
C5 + TMU VFD
MF06MK200
No radius
Straight
track
only
The TMU variable frequency drive is available for power supply of 208, 230, 460 or 575v through the use of
an autotransformer. In addition, a line reactor is used to protect the TMU VFD against voltage spikes. Both
the autotransformer and the line reactor are mounted to the trolley idler side plate under a cover. For a power
supply of 400v/50Hz, a transformer is not required. The VFD controls are totally enclosed, and the enclosure
is mounted to the motor.
y
Control
Type: Variable
Frequency
Drive
y
Main power supply:
208, 230, 400/50Hz, 460 or 575 VAC
y
Control voltage:
115 VAC (48v optional; std. with 400v)
y
Frequency:
50/60Hz
y
Speed control method:
2 speed mode (default) or Infinitely variable
y
Stopping
method:
Dynamic
braking
y
Brake
Type:
COMPACT
Brake
y
Acceleration/Deceleration:
2.50
seconds
(default)
y
Motor overload protection:
Bimetal switch (option)
y
Protection:
IP-55
(NEMA
3R
type
enclosure)
y
Approvals:
CSA
“C”
and
“US”
Gearless TMU Variable Frequency Drive (loads < 1 ton [1000 kg])
y
Nominal output power of gearless TMU:
0.2 hp [0.15 kW]
y
Travel
speeds:
65/16
fpm
[20/5
m/min]
y
Motor
frequency:
35
Hz
y
Motor
Type:
MF06MK200
gearless
y
Starting
Current
2.3A
y
Nominal
Current
1.1A
Geared TMU Variable Frequency Drive (loads >1 ton [1000 kg]) at 460v-60Hz
y
Nominal output power of geared TMU:
0.5 hp [0.37 kW]
y
Travel
speeds:
65/16
fpm
[20/5
m/min]
y
Motor
frequency
100
Hz
y
Motor
Type:
MF06MK200
y
Starting
Current
4.3A
y
Nominal
Current
1.2A
The inverter can be programmed to achieve a wide range of minimum and maximum travel speeds. See
Section 4.2.1 for more information regarding the travel speed settings.