Communication port, 1 rs-232 and usb communication ports, 2 rs-232 port – PowerWalker Battery Pack for VFI 1000RT LCD User Manual
Page 39
35
EN
11. Communication Port
11.1 RS-232 and USB communication ports
To establish communication between the UPS and a computer, connect a
computer to one of the UPS communication ports by using an applicable
communication cable.
11.2 RS-232 port
The RS-232 port is available for UPS monitoring, control, and firmware
updates. To establish communication between the UPS and a computer,
connect one end of the serial communication cable that comes with the UPS
to the RS-232 port on the UPS. Connect the other end of the serial cable to
the RS-232 port on a computer.
The cable pins for the RS-232 communication port are identified in the
following illustration.
RS-232 communication port pin assignments
Pin Signal name
Function
Direction from
the UPS
1
Unused
Not applicable
2
Tx
Transmit to external device
Out
3
Rx
Receive from external device In
4
Unused
Not applicable
5
GND
Signal common
(tied to chassis)
Not applicable
6
Unused
Not applicable
7
Unused
Not applicable
8
Unused
Not applicable
9
Unused
Not applicable
NOTE:
Only one of the communication ports can be active at one time. The USB port has
priority over the RS-232 port.
When a communication cable is installed, the power management software can
exchange data with the UPS. The software polls the UPS for detailed information
on the status of the power environment. If a power emergency occurs, the
software initiates the saving of all data and an orderly shutdown of the equipment