Connecting multiple EBMs in Tower form

1. Connect Earth line between UPS and the first EBM, and then connect Earth

Line between the first EBM and the second EBM.

2. Take off the front panel, and connect the battery terminal (A) from UPS to

EBM terminal (B) shown as below. And then connect the battery terminal

(D) from the first EBM to the battery terminal (E) from the second EBM.

Users need to remove the small gate(C) on side of the front panel to allow

the outlet wire of the EBM to pass through the gate and then reassemble

front panel.










Connecting the Multiple EBMs in rack form

1. Connect Earth line between UPS and the first EBM, and then connect

Earth Line between the first EBM and the second EBM.

2. Take off the front panel, and connect the battery terminal (A) from UPS to

EBM terminal (B) shown as below. And then connect the battery terminal

(D) from the first EBM to the battery terminal (E) from the second EBM.

Users need to remove the small gate(C) on side of the front panel to allow

the outlet wire of the EBM to pass through the gate and then reassemble

front panel.