OBDII Streamer Command & Response

V2.11

Page 48/49

Component file structures




The FPGA hardware/firmware image, the Database image and the Bootloader images
follow Motorola SREC format. The System manager image follows Intel Hex format.

Database image will be updated in the same manner as firmware/hardware image since
represented in the same file structure (SREC format).

System Bootloader image will be updated in the same manner as firmware/hardware
image since represented in the same file structure (SREC format).

Firmware File Naming Conventions
Firmware files will all have a .flash extension and be named as follows:
FPGA_Firmware_Only_v_VERSION.flash,
where VERSION is the Major and two Minor version numbers of the firmware.
ex. FPGA_Firmware_Only_v_2.1.3.flash


EEPROM Database File Naming Conventions
Database files will all have a .flash extension and be named as follows:
V2_DB_VERSION.flash,
where VERSION is the Major and two Minor version numbers of the database.
ex. V2_DB_2_3_1.flash