beautypg.com

B&B Electronics LDVDSV2-S-P9D - Manual User Manual

Page 34

background image

OBDII Streamer Command & Response

V2.11

Page 34/49

TVALUE

Threshold Value


This field is two bytes long and will configure the threshold value
used to determine when to send a message. The value in this field
should be passed to the Intelligent OBDII Streamer using reverse
scaling.


CS

Summation checksum


Example:
This command sets up the vehicle speed PID to be transmitted when the vehicle speed is
greater than 40 MPH.

TX:
0x01 0x01 0x31 0x04 0x00 0x01 0x40 0x10 0x88

RX:
0x01 0x01 0xB1 0x04 0x00 0x01 0x40 0x10 0x08

Threshold Value = 0x4010 = 16400

16400 / 410 = 40MPH

Unknown Delay. The following message will be received every time the parameter is
updated AND the vehicle speed parameter is over 40 MPH.

RX:
0x01 0x01 0xC1 0x03 0x00 VEHICLE_SPEED CS

0x32 – SET_FULLSPEED_UPDATES (Obsolete)

Description:
This command is no longer supported as of Streamer version 2.