B&B Electronics ZXT9-IO-222R2 - Quick Start Guide User Manual

Page 2

background image

pn 8590R1-ZXTx-IO-x-2011QSG –Peer-to-Peer Mode

S

S

t

t

a

a

r

r

t

t

Z

Z

l

l

i

i

n

n

x

x

I

I

/

/

O

O

M

M

a

a

n

n

a

a

g

g

e

e

r

r

‰

Connect the USB port of your PC to the Zlinx Xtreme I/O
module using a USB cable.

‰

Click Start\Programs\B&B Electronics\Zlinx\Zlinx
Manager\Zlinx Manager, then click Zlinx I/O and then
Zlinx I/O Configuration. It will auto-search for attached
Zlinx Xtreme I/O Module on startup. Zlinx I/O will open
and display the Information tab showing the I/O model
number, version numbers and firmware rev levels.



C

C

o

o

n

n

f

f

i

i

g

g

u

u

r

r

e

e

C

C

o

o

m

m

m

m

u

u

n

n

i

i

c

c

a

a

t

t

i

i

o

o

n

n

M

M

o

o

d

d

e

e

On the Configuration tab:

‰

Configure Wireless settings:

o

Select the desired RF Transmit Power

o

Set the Channel Number to match the Modbus Radio
Modem you will be communicating with.

o

Set the Network Identifier to match the Modbus
Radio Modem you will be communicating with.

o

Set Repeater checkbox if desired. Note that ONLY
the (ZXT9-IO- xx) modules supports this mode.

‰

Set encryption key to match that of the Modbus radio
modem.

‰

Select the communication mode to ‘Modbus’ Mode.

‰

Set the Modbus address to the address number desired
for the Module being configured.

‰

Click Update to save configuration.


C

C

o

o

n

n

f

f

i

i

g

g

u

u

r

r

e

e

I

I

n

n

p

p

u

u

t

t

s

s

/

/

O

O

u

u

t

t

p

p

u

u

t

t

s

s

‰

Set Digital Inputs for Discrete or Counter, as required.

o

Choose PNP or NPN selection as appropriate.
Each input is individually configurable.

‰

Configure Digital Relay Outputs. Enable the Fail Safe
and Communications Fail Alarm if necessary.

‰

Configure each Analog Inputs and Outputs in one of the
following modes

7

o

0-5V, 0-10V, 0-20mA, 4-20mA

Refer to Zlinx Xtreme I/O manual for more details

‰

Set Exception Reporting for Analog Inputs and Fail Safe
settings for Analog Outputs if necessary.

‰

Set Calibration option if you desire to better match a
sensor, or a portion of a signal, to the I/O.

‰

Refer to appropriate sections in the Zlinx Xtreme I/O
manual.

‰

Click Update button to apply the settings.


O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

10

LED

STATUS

FUNCTION

Power

Solid
Flash

Power applied
Communication Fail

RSSI
(8 LED
bar
graph)

0
1-3
4-6
7-8

No signal
Weak signal
OK signal
Strong signal

Wireless

Off
Blinking

No radio link data
Wireless data Transmit / Receive

Mode

Modbus
P2P Master
P2P Slave

Modbus Mode
Peer-to-Peer Master
Peer-to-Peer Slave

I/O
Status

DI1
DI2
DO1
DO2

Digital Input 1 ON
Digital Input 2 ON
Digital Output (Relay) 1 ON
Digital Output (Relay) 2 ON

9

8

U

U

L

L

C

C

l

l

a

a

s

s

s

s

1

1

D

D

i

i

v

v

2

2

R

R

e

e

q

q

u

u

i

i

r

r

e

e

m

m

e

e

n

n

t

t

s

s

11

‰

Operating Voltage – 10 to 30 VDC

‰

WARNING: SUITABLE FOR USE IN CLASS I, DIVISION 2,
GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR
NONHAZARDOUS LOCATIONS ONLY.