MAX1363/MAX1364

4-Channel, 12-Bit System Monitors with Programmable
Trip Window and SMBus Alert Response

14

______________________________________________________________________________________

START

CONDITION

START

ADDRESS

FROM THE MASTER

CONFIGURATION

BYTE FROM THE MASTER

SETUP

BYTE FROM THE MASTER

0

A

A

A

STOP

R/W BIT FROM

THE MASTER

Figure 8. Example of Writing Setup and Control Bytes

START

CONDITION

START

ADDRESS

FROM THE MASTER

SETUP BYTE

FROM THE MASTER

ALARM RESET, SCAN

SPEED, BYTE FROM MASTER

0

A

1

A

A

CH 0 LT [11:4] BYTE

CH 0 LT [3:0];

UT [11:8] BYTE

CH 1 LT [11:4] BYTE

CH 0 UT [7:0] BYTE

A

A

A

A

STOP

R/W BIT FROM

THE MASTER

Figure 9. Example of Extended Setup Byte Writing

BIT

NAME

DESCRIPTION

7(MSB)

CONFIG

The configuration byte always starts with 0.

6

SCAN1

5

SCAN0

SCAN1, SCAN0 = [0,0], scans from channel 0 to the upper channel chosen by CS1, CS0.
SCAN1, SCAN0 = [0,1], converts a single channel chosen by CS1, CS0 eight times.
SCAN1, SCAN0 = [1,0] monitor mode monitors from channel 0 to the upper channel chosen by CS1, CS0.
SCAN1, SCAN0 = [1,1], single channel conversion for the channel is chosen by CS0, CS1.

4

CS3

3

CS2

CS3, CS2 = [1,1] enables readback of monitor-mode setup data.

2

CS1

1

CS0

Selects the upper limit of the channel range used for the conversion sequence in scan modes SCAN = [0,0]
and monitor modes SCAN = [1,0].
Selects the conversion channel when SCAN = [0,1] or when SCAN = [1,1].
(Tables 5 and 6)

0

SE/DIF

1 = single-ended inputs.
0 = differential inputs.
AIN0 and AIN1 form the first differential pair and AIN2 and AIN3 form the second differential pair. (See Tables
4 and 5.)
Selects single-ended or differential conversions. In single-ended mode, input-signal voltages are referenced
to GND. In differential mode, the voltage difference between two channels is measured.
When single-ended mode is used, the MAX1363/MAX1364 perform unipolar conversions regardless of the
UNI/BIP bit in the setup byte.
(Table 7)

Table 2. Configuration Byte Format*

*Power-on defaults: 0x01