19 registers 6a-6ch: absolute temperature limit, Table 11. absolute limit vs register setting, 20 registers 6d-6eh: zone hysteresis registers – Rainbow Electronics LM96000 User Manual
Page 24: Functional description

Functional Description
(Continued)
TABLE 10. Temperature Limit vs Register Setting (Continued)
Temperature
Reading (Decimal)
Reading (Hex)
0˚C
0
00h
.
.
.
.
.
.
.
.
.
50˚C
50
32h
.
.
.
.
.
.
.
.
.
127˚C
127
7Fh
4.19 Registers 6A-6Ch: Absolute Temperature Limit
Register
Address
Read/
Write
Register
Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
Lock?
6Ah
R/W
Zone1 Absolute Temp Limit
7
6
5
4
3
2
1
0
64h
U
6Bh
R/W
Zone2 Absolute Temp Limit
7
6
5
4
3
2
1
0
64h
U
6Ch
R/W
Zone3 Absolute Temp Limit
7
6
5
4
3
2
1
0
64h
U
In the Auto Fan mode, if a zone exceeds the temperature set in the Absolute Temperature Limit register, all of the PWM outputs
will incresase its duty cycle to 100%. This is a safety feature that attempts to cool the system if there is a potentially catastrophic
thermal event. If set to 80h (-128˚C), the feature is disabled. Default=100˚C=64h
These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to
these registers shall have no effect. After power up the default values are used whenever the Ready/Lock/Start/Override register
Start bit is cleared even though modifications to these registers are possible.
TABLE 11. Absolute Limit vs Register Setting
Temperature
Reading (Decimal)
Reading (Hex)
−127˚C
−127
81h
.
.
.
.
.
.
.
.
.
−50˚C
−50
CEh
.
.
.
.
.
.
.
.
.
0˚C
0
00h
.
.
.
.
.
.
.
.
.
50˚C
50
32h
.
.
.
.
.
.
.
.
.
127˚C
127
7Fh
4.20 Registers 6D-6Eh: Zone Hysteresis Registers
Register
Address
Read/
Write
Register
Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
Lock?
6Dh
R/W
Zone1 and Zone2 Hysteresis
H1-3
H1-2
H1-1
H1-0
H2-3
H2-2
H2-1
H2-0
44h
U
6Eh
R/W
Zone3 Hysteresis
H3-3
H3-2
H3-1
H3-0
RES
RES
RES
RES
40h
U
If the temperature is above Fan Temp Limit, then drops below Fan Temp Limit, the following will occur:
LM96000
www.national.com
24