4967DS–RFID–10/08

ATA5577 [Preliminary]

Block 0 of page 0 contains the mode/configuration data, which is not transmitted during regular
read operations. Addressing block 0 will always affect block 0 of page 0 regardless of the page
selector. Block 7 of page 0 may be used as a write-protection password.

Block 3 of page 1 contains the option register, which is not transmitted during regular-read
operation.

Bit 0 of every block is the lock bit for that block. Once locked, the block (including the lock bit
itself) is not re-programmable via the RF field.

Blocks 1 and 2 of page 1 contain traceability data and are transmitted with the modulation
parameters defined in the configuration register after the opcode “11” is issued by the reader.
The traceability data blocks are programmed and locked by Atmel.

5.

Absolute Maximum Ratings

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.

Parameters

Symbol

Value

Unit

Maximum DC current into Coil1/Coil2

I

coil

20 (TBD)

mA

Maximum AC current into Coil1/Coil2, f = 125 kHz

I

coil p

20 (TBD)

mA

Power dissipation (die) (free-air condition, time of
application: 1s)

P

tot

100 (TBD)

mW

Electrostatic discharge maximum to
ANSI/ESD-STM5.1-2001 standard (HBM)

V

max

2000 (TBD)

V

Operating ambient temperature range

T

amb

–40 to +85

°C

Storage temperature range (data retention
reduced)

T

stg

–40 to +150

°C