beautypg.com

Rainbow Electronics GE863-PY User Manual

Page 38

background image





GE863 Hardware User Guide

1vv0300783 Rev.0 - 10/06/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 38 of 80

The signals of the GE863 serial port are:

RS232 Pin

Number

Signal

GE863 Pad

Number

Name

Usage

1

DCD -

dcd_uart

42

Data Carrier Detect

Output from the GE863 that indicates the carrier

presence

2

RXD -

tx_uart

38

Transmit line *see Note

Output transmit line of GE863 UART

3

TXD -

rx_uart

37

Receive line *see Note

Input receive of the GE863 UART

4

DTR -

dtr_uart

39

Data Terminal Ready

Input to the GE863 that controls the DTE READY

condition

5

GND

8-17-28-36-45-

48-50-56

Ground

ground

6

DSR -

dsr_uart

43

Data Set Ready

Output from the GE863 that indicates the module is

ready

7

RTS -

rts_uart

40

Request to Send

Input to the GE863 that controls the Hardware flow

control

8

CTS -

cts_uart

41

Clear to Send

Output from the GE863 that controls the Hardware

flow control

9

RI -

ri_uart

44

Ring Indicator

Output from the GE863 that indicates the incoming

call condition

NOTE: According to V.24, RX/TX signal names are referred to the application side, therefore on the GE863 side
these signal are on the opposite direction: TXD on the application side will be connected to the receive line (here
named TXD/ rx_uart ) of the GE863 serial port and viceversa for RX.

TIP: For a minimum implementation, only the TXD and RXD lines can be connected, the other lines can be left open
provided a software flow control is implemented.

TIP: In order to avoid noise or interferences on the RXD lines it is suggested to add a pull up
resistor (100Kohm to 2.8V)