Connector description, 1 power supply, 2 cameralink connector – Rainbow Electronics ATMOS™ 1M60 User Manual
Page 21

21
5429B–IMAGE–04/05
[Preliminary] ATMOS -1M60/1M30
7.
Connector Description
All connectors are on the rear panel. Better results are obtained by using shielded cables (foil
and braid shielded).
Note: cables for digital signals shall be twisted pairs.
7.1
Power Supply
Camera connector type: Hirose HR10A-7R-6PB (male)
Cable connector type: Hirose HR10A-7P-6S (female)
Figure 7-1.
Power Supply Pinout
7.2
CameraLink Connector
Standard CameraLink cable shall be used to ensure the full electrical compatibility.
• Camera connector type: MDR-26 (female) ref. 3M 10226-2210VE
• We recommend to use a CameraLink standard shielded cable as 3M 14X26-SZLB-XXX-0LC
Figure 7-2.
CameraLink Pinout
Power Connector : J01
Signal
Pin
Signal
Pin
PWR
1
GND
4
NC
2
NC
5
PWR
3
GND
6
1
2
3
6
5
4