PHOTOMETRICS
WEIGHTS & SUPPORT SPACING
CONFIGURATIONS
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
INTEGRATED NLIGHT MICRO SENSOR
PLAN VIEW
STANDARD SECTIONS
4’-0
1
⁄
4
”
9
⁄
16
” end plate
4’-1
3
⁄
8
” O.A.
8’-0
1
⁄
8
”
8’-1
1
⁄
4
” O.A.
12’-0”
12’-1
1
⁄
8
” O.A.
Key:
•
Support or feed location
Type:
________________________
Project:
______________________
24 LBS
43 LBS
62 LBS
Mitered corner, “T” and “X” connectors available for suspended configurations.
Referenc
for additional details.
Actual performance may differ as a result of end-user environment and application.
2
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Envision” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T8
Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations.
Network Type & Sensor Power Source (choose one)
1*
nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack
10’ Cat-5e cable and splitter provided
2
Standalone Operation (No Networking) with Luminaire Integrated Power Pack
No Cat-5e cable provided
3*
nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel
10’ Cat-5e cable and splitter provided
Order required remote nLight Power Pack or nPanel
separately through nLight (Acuity Brands Controls)
Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number.
EXAMPLE:
PDT1
Sensor Type (choose one)
ADC
nLight model
nES ADCX
Daylight Dimming
Specify 0-10V dimming ballast
No occupancy sensing
PDT
nLight model
nES PDT7 ADCX
Daylight Dimming and/or Occupancy Detection
Specify 0-10v dimming ballast for daylight dimming
Specify fixed-output ballast for occupancy detection only
(daylight dimming disabled)
For more information about the Integrated nLight Micro Sensor, its capabilities and options, do
*nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on
wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact [email protected].
Suspended
ENM1
1-LAMP T8
85.3% efficiency
2430 delivered lumens
100.0% up / 0.0% down
2-LAMP T8
83.0% efficiency
4733 delivered lumens
100.0% up / 0.0% down
3-LAMP T8
80.5% efficiency
6880 delivered lumens
100.0% up / 0.0% down