Peerless Lighting BRW1 - T5_T5HO User Manual
Bruno wall, Indirect indirect t5/t5ho, Wall mount
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
1
3
⁄
4
”
8
1
⁄
4
”
1
3
⁄
4
”
8
1
⁄
4
”
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T5/T5HO
BRW1 Bruno Wall
Examples:
BRW1 2 28T5 WHR 40FT R8 120 GEB10 DCT LP835 C210 SCEP — BRW1 2 54T5HO WHR 32FT R8 277 GEB10 1SE EL DCT LP835 C110
Bruno Wall
Indirect
Indirect T5/T5HO
Wall Mount
BRW1
BRW1- 2
BRW1 - 1
Construction
Nominal 8
1
⁄
4
” x 1
3
⁄
4
” rectangular housing is formed
from cold-rolled steel. Die-cast end caps are
mechanically attached with no exposed fasteners.
Reflectors
Die-formed white painted reflector.
Finish
Fine-textured, white polyester powder paint
is standard. Consult factory for special finish
requirements.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’
1
⁄
16
”, 8’ and 12’ lengths in a single section. For
total luminaire length, add
5
⁄
8
” for each flat end cap
and 4” for each sculptured end cap. Using internal
joiners, 4’, 8’ and 12’ sections can be joined to form
longer rows.
SCEP Option
__________
__________
__________
__________
_________
__________
__________
__________
__________
Luminaire
BRW1
# of Lamps in
Cross Section
1
2
Lamp Type
28T5 28W T5
54T5HO 54W T5HO
Reflector
WHR White
reflector
Luminaire Row
Length
X FT
(4’ increments)
Maximum
Section Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1,2
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1,2
Osram 0-10V dim
Referenc
or consult factory for other options.
# of Emergency Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
______________
________________
________________
______________
_________________________________
Emergency Type
3
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
Switching
SCT
Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+ CRI Premier
LP835P 3500K 80+ CRI Premier
LP841P 4100K 80+ CRI Premier
Referenc
consult factory for other options.
Finish
C110 Painted aluminum
(low gloss)
C210 White white
(fine-textured
low gloss)
C099 Custom finish
Options
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code
SCEP Sculptured end cap
Notes:
1 Not available in 347V
2 Not available with 28T5 lamps
3 Emergency type is installed in last 4’ of luminaire
sections. Separate feed required unless ELS or ELS2 is
specified