beautypg.com

Peerless Lighting PRM4 - T5_T5HO User Manual

Prima i/d, Indirect-direct t5/t5ho, Suspended

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Prima” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

PRM4  Prima I/D

Examples:

PRM4 1 54T5HO SPR OPD WPB 40FT R12 120 GEB10 2SE EL SCT LP841 F1/24 C110 — PRM4 2 54T5HO WHR OPD SSB 12FT R8 277 GEB10 DCT LP830 F2/15 C518 GLR

Suspended

PRM4

Prima I/D

Indirect-Direct T5/T5HO

PRM4 - 1

PRM4 - 2

PRM4 - 3

9”

3”

9”

3”

9”

3”

Construction

9” x 3” one-piece cold-rolled steel housing with flat

end plate.

Reflectors

Die-formed highly reflective white or specular

reflector.

Shielding

Semi-specular parabolic aluminum baffles.

Finish

Fine-textured, white paint or silver paint to match

anodized aluminium are standard. Custom colors

available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’

1

4

”, 8’ and 12’ lengths in a single section for

exact suspension spacing of 4’, 8’ and 12’. For total

luminaire length add

1

16

” for each end cap. Using

internal joiners, 4’, 8’ and 12’ sections can be joined

to form longer-length luminaires.

__________

__________

__________

__________

__________

__________

_________

__________

__________ __________

Luminaire

PRM4

# of

Lamps in

Cross

Section

1

2

3

28T5 28W T5

54T5HO 54W T5HO

Reflector

WHR White

Reflector

(Standard)

SPR Specular

Reflector

Shielding

OPD Baffle

w/std

brightness

opal

diffuser

overlay

Baffle

SSB Semi-

specular

baffle

WPB White

painted

baffle

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

______________

________________

__________

________________

______________

______________

______________

_________________________________

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

3

(Blank) None

EC Emergency

circuit

EL

1

Emergency

battery pack

EN

1

Emergency

battery pack

w/night light

circuit

Switching

SCT Single

circuit

DCT Dual

circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

F3/

Rigid stem

Overall

Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall

suspension is

measured from

ceiling to bottom

of luminaire.

Finish

C110 Painted

aluminum

(low gloss)

C518 White (fine-

textured low

gloss)

C099 Custom

finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not

available with F3)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed,

shared neutral

ELS2

Emergency through wiring w/single feed,

separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified

with F2, ACG and OJB options)

XXXX Integrated sensor; choose options and obtain

code on page 2

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 EL and EC are installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified