Peerless Lighting 10CRM1 - T8 User Manual
Cerra 10 indirect, Indirect t8, Suspended
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T8
10CRM1 Cerra 10
Examples:
10CRM1 2 32 WHR 40FT R12 277 GEB10 DCT LP835 F1/18 SCEP — 10CRM1 3 32 SPR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21
Suspended
10CRM1
Cerra 10 Indirect
Indirect T8
10CRM1 - 2
2
5
⁄
8
”
10”
10CRM1 - 4
10CRM1 - 3
2
5
⁄
8
”
10”
2
5
⁄
8
”
10”
10CRM1 - 1
2
5
⁄
8
”
10”
SCEP Option
Construction
Nominal 10” x 3” crescent housing is formed from
one-piece cold-rolled steel. Flat end plate standard.
Sculptured die-cast aluminum end cap is optional.
Reflectors
Die-formed highly reflective white or specular
reflector.
Finish
Fine-textured, white or aluminum polyester
powder paint. Custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section for exact
suspension spacing of 4’, 8’, and 12’. For total
luminaire length, add
1
⁄
16
” for each flat end plate
or 4” for each sculptured end cap. Using internal
joiners, 4’, 8’, and 12’ sections can be joined to form
longer length luminaires.
__________
__________
__________
__________
_________
__________
__________ __________
__________
__________
Luminaire
10CRM1
# of
Lamps in
Cross
Section
1
2
3
4
Lamp Type
32
32W T8
Reflector
WHR White
Reflector
(Standard)
SPR Specular
reflector
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V
dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
______________
________________
______________
______________
______________
_________________________________
Switching
SCT
Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy saving
lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Referenc
website or consult factory
for other options.
Mounting Type /
F1/
T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/
Hard ceiling (horizontal
J-box)
F3/
Rigid stem
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is measured
from ceiling to bottom of
luminaire.
Finish
C110 Painted aluminum
(low gloss)
C210 White white
(fine-textured
low gloss)
C099 Custom finish
Options
ACG
Adjustable cable grippers
BLK
Black cord, cord manager and canopy (not available with F3)
CP
Chicago plenum (available with F1A only)
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2
Emergency through wiring w/single feed, separate neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
MCS
Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC
New York City code
OJB
Offset junction box
SCEP
Sculptured end cap
SLP
Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
XXXX Integrated sensor; choose options and obtain code on page 2
Notes:
1 Not available in 347V
2 EL and EC are installed in last 4’ of luminaire sections and are not available concurrently
with each other. Separate feed required for each EL or EC unless ELH is specified