beautypg.com

Peerless Lighting BRM7 - T5_T5HO User Manual

Bruno, Partial perforation indirect t5/t5ho, Suspended

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

BRM7 2 T5/T5HO WHR

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect T5/T5HO

BRM7  Bruno  Partial Perforation

Examples:

BRM7 2 28T5 SPR 40FT R8 277 GEB10 DCT LP835 F1/18 C210 SCEP — BRM7 2 54T5HO SPR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110

Suspended

BRM7

SCEP Option

1

3

4

8

1

4

BRM7 - 2

Construction

Nominal 8

1

4

” x 1

3

4

” rectangular housing is formed

from cold-rolled steel. Die-cast end caps are

mechanically attached with no exposed fasteners.

Reflectors

Die-formed specular reflector with 95% reflectance.

Shielding

Die-punched perforations with acrylic opal

diffuser overlay.

Finish

Fine-textured, white polyester powder paint

is standard. Consult factory for special finish

requirements.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’

3

8

”, 8’ and 12’ lengths in a single section for

nominal support spacing at 4’, 8’ and 12’. For total

luminaire length, add

5

8

” for each flat end cap

and 4” for each sculptured end cap. Using internal

joiners, 4’, 8’ and 12’ sections can be joined to form

longer rows.

__________

__________

__________

__________

_________

__________

__________ __________

__________

__________

Luminaire

BRM7

# of

Lamps in

Cross

Section

2

Lamp Type

28T5

1

28W T5

54T5HO 54W T5HO

Reflector

SPR Specular

reflector

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

2

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery pack

EN

1

Emergency battery pack

w/night light circuit

______________

________________

______________

______________

______________

_________________________________

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

F3/

Rigid stem

Overall Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall suspension is measured

from ceiling to bottom of

luminaire.

Finish

C110 Painted aluminum

(low gloss)

C210 White white

(fine-textured

low gloss)

C099 Custom finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not available with F3)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2

Emergency through wiring w/single feed, separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SCEP

Sculptured end cap

SLP

Sloped ceiling (for 10-45°, must be specified with F2, ACG and

OJB options)

XXXX Integrated sensor; choose options and obtain code on page 2

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

Bruno

Partial Perforation