beautypg.com

Peerless Lighting CRW3 - T5_T5HO User Manual

Cerra wall, Lightvent indirect-direct t5/t5ho, Wall mount

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

CRW3  Cerra Wall  Lightvent

Wall Mount

CRW3

Cerra Wall

Lightvent

Indirect-Direct T5/T5HO

Examples:

CRW3 1 54T5HO WHR 40FT R12 277 GEB10 SCT LP835 C210 SCEP — CRW3 2 54T5HO SPR 32FT R8 277 GEB10 1SE EL DCT LP835 C110

Construction

Housing is formed from one-piece cold-rolled

steel. Flat end plate standard. Sculptured die-cast

aluminum end cap is optional.

Reflectors

Die-formed highly reflective white or specular

reflector.

Shielding

Die-punched perforated window on lower housing

with acrylic opal diffuser overlay.

Finish

Fine-textured, white or aluminum polyester powder

paint. Custom colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

Nominal 4’, 8’, and 12’ sections form row lengths.

Consult factory for 2’ and 3’ sections. For total run

length, add

1

16

” for each flat end plate or 4” for each

sculptured end cap. For longer run lengths, sections

are attached using internal joiners.

__________

__________

__________

__________

_________

__________

__________ __________

__________

Luminaire

CRW3

# of

Lamps in

Cross

Section

1

2

Lamp Type

28T5 28W T5

54T5HO 54W T5HO

Reflector

WHR White

Reflector

(Standard)

SPR Specular

Reflector

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

__________

________________

______________

_________________________________

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

Emergency battery pack

EN

Emergency battery pack

w/night light circuit

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+ CRI Premier

LP835P 3500K 80+ CRI Premier

LP841P 4100K 80+ CRI Premier
Reference

Lamp Chart

on website or

consult factory for other options.

Finish

C110 Painted aluminum (low gloss)

C210 White white (fine-textured low gloss)

C099 Custom finish

Options

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

SCEP Sculptured end cap

Optional sculptured end cap

CRW3 - 1

CRW3 - 2

7

5

8

2

11

16

7

5

8

2

11

16

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 EL and EC are installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified