Peerless Lighting LLML (Sur) - T5_T5HO User Manual
Lightline softshine direct, Direct t5/t5ho, Surface
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
3
⁄
8
”
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightline” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Direct T5/T5HO
LLML Lightline Softshine
Surface
LLML
Lightline Softshine
Direct
Direct T5/T5HO
Examples:
LLML S 1 28T5 SSH 7FT3IN R8 277 GEB10 1SE EC SCT LP835 C041
Construction
Extruded aluminum housing forms a 3
5
⁄
8
” x 4
1
⁄
16
”
rectangular profile. Die-cast aluminum end caps
mechanically attach with no exposed fasteners.
Shielding
Softshine high performance lens controls light
distribution. Uniform luminance along the length of
the lens is achieved with staggered lamps.
Reflectors
High reflectance white painted reflector system.
Finish
Satin anodized finish consists of satin anodized
housing with end caps painted to match. Custom
colors available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
Stand alone sections are 3’10” (R4), 7’3” (R8), and
10’8” (R12). Rows are comprised of starter, joiner
and ender sections of various lengths. Refer to
planning guide for details. For total luminaire length,
add
7
⁄
8
” for each end cap.
__________
__________
__________
__________
__________
_________
__________
__________ __________
Luminaire
LLML
Mounting Type
S Surface
# of Lamps in
Cross Section
1
Lamp Type
28T5 28W T5
54T5HO 54W T5HO
Shielding
SSH Softshine
lens
Luminaire Row Length
2
3FT10IN Individual (R4)
7FT3IN Individual (R8)
10FT8IN Individual (R12)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
3,4
Advance Mark 10 dim
DMHL3D
3
Lutron Hi-Lume dim
OSDIM
3,4
Osram 0-10V dim
Referenc
or consult factory for other options.
______________
_____________
_____________
________________
______________
_________________________________
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
4
(Blank) None
EC
Emergency circuit
EL
3
Emergency battery pack
EN
3
Emergency battery pack
w/night light circuit
Switching
SCT
Single circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+
CRI Premier
LP835P 3500K 80+
CRI Premier
LP841P 4100K 80+
CRI Premier
Referenc
website or consult factory
for other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
DL
Damp location label
ELS
Emergency through wiring w/single feed, shared neutral
ELS2
Emergency through wiring w/single feed, separate neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
NEPP5D nLight enabled control module per row/zone
NYC
New York City code
XXXX Integrated sensor; choose options and obtain code on page 2
LLML S
3
5
⁄
8
”
4
1
⁄
16
”
Notes:
1 Available with individual units only (3FT10IN, 7FT3IN, 10FT8IN)
2 Available in individual only
3 Not available in 347V
4 Not available with 28T5 lamps
5 Emergency type is installed in last 4’ of luminaire sections. Separate
feed required unless ELS or ELS2 is specified