beautypg.com

Peerless Lighting EGRM9 - T5_T5HO User Manual

Lightedge rectangular softshine or grateoptic, Indirect t5/t5ho, Suspended

background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

8

1

8

8

1

8

8

1

8

8

1

8

8

1

8

8

1

8

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightedge” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect T5/T5HO

EGRM9  Lightedge Rectangular Softshine or GrateOptic

Lightedge Rectangular

Softshine or GrateOptic

Indirect T5/T5HO

Suspended

EGRM9

Examples:

EGRM9 2 54T5HO SSH 40FT R8 120 GEB10 2SE EL SCT LP835 F1/24 C100 — EGRM9 2 54T5HO GTO 32FT R8 277 GEB10 DCT L/LP F2/15 C100 ACG

Construction

Housing and end caps are extruded aluminum

forming an 8

1

8

” x 1

1

2

” rectangular profile.

Reflectors

Die-formed white painted reflector (nominal

reflectance 90%) and specular aluminum

side reflector.

Shielding

Crenulated GrateOptic® diffuser or flush Softshine®

high performance lens.

Finish

Satin anodized standard. Custom colors available,

consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’ and 8’ lengths in a single section for exact

suspension spacing of 4’ and 8.’ For total luminaire

length add 4” for each end cap. Using internal

joiners, 4’ and 8’ sections can be joined to form

longer-length luminaires.

__________

__________

__________

_________

_________

__________

__________ __________

__________

__________

Luminaire

EGRM9

# of Lamps

in Cross

Section

1

2

3

Lamp Type

28T5

1

28W T5

54T5HO 54W T5HO

Shielding

GTO GrateOptic

SSH Softshine

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section Length

R4

4’ section(s)

R8

8’ section(s)

Voltage

120

277

347

2

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery

pack

EN

1

Emergency battery

pack w/night light

circuit

______________

________________

______________

______________

______________

_________________________________

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

Overall Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall suspension is measured

from ceiling to bottom of

luminaire.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

Dust cover (not available with 3-lamp cross section)

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2

Emergency through wiring w/single feed, separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified with F2, ACG

and OJB options)

XXXX Integrated sensor; choose options and obtain code on page 2

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

SSH

GTO

EGRM9 - 1 - GTO

EGRM9 - 1 - SSH

EGRM9 - 2 - GTO

EGRM9 - 2 - SSH

EGRM9 - 3 - GTO

EGRM9 - 3 - SSH