Peerless Lighting ENW1 - T8 User Manual
Envision wall, Indirect t8, Wall mount
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Envision” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T8
ENW1 Envision Wall
Wall Mount
ENW1
Examples:
ENW1 010005 T8 36FT R12 120 GEB10 2SE EL SCT LP835 C041 — ENW1 020006 T8 24FT R8 277 GEB10 DCT LP841 C041
Envision Wall
Indirect T8
ENW1 - 1
ENW1 - 2
3”
9”
3”
9”
Construction
Housing is extruded aluminum forming a 9” x 3”
curved profile. Die-cast end plate attaches with no
exposed fasteners.
Reflectors
Die-formed, pre-finished steel and hammertone
specular aluminum reflector.
Finish
Satin anodized or white paint standard. Custom
colors available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section. For total
luminaire length add
1
⁄
2
” for each end cap. Using
internal joiners, 4’, 8’, and 12’ sections can be joined
to form longer-length luminaires. Individual 2’ and 3’
units also available, consult factory.
________
________
________
________
________
________
________________________
______________
______________
Luminaire
ENW1
# of Lamps
in Cross
Section
010005 1
020006 2
Lamp Type
32
32W T8
Nominal
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R2
2’ section(s)
R3
3’ section(s)
R4
4’ section(s)
R8
8’ section(s)
R12
12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
2
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery
pack
EN
1
Emergency battery
pack w/night light
circuit
________
________________
______________
_________________________________
Switching
SCT
Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired for energy
saving lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Referenc
consult factory for other options.
Finish
C041 White white (low gloss)
C100 Satin anodized finish
C099 Custom finish
Options
CFG Configuration
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified