LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Envision” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect T8

ENW1  Envision Wall

Wall Mount

ENW1

Examples:

ENW1 010005 T8 36FT R12 120 GEB10 2SE EL SCT LP835 C041 — ENW1 020006 T8 24FT R8 277 GEB10 DCT LP841 C041

Envision Wall

Indirect T8

ENW1 - 1

ENW1 - 2

3”

9”

3”

9”

Construction

Housing is extruded aluminum forming a 9” x 3”

curved profile. Die-cast end plate attaches with no

exposed fasteners.

Reflectors

Die-formed, pre-finished steel and hammertone

specular aluminum reflector.

Finish

Satin anodized or white paint standard. Custom

colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’, and 12’ lengths in a single section. For total

luminaire length add

1

2

” for each end cap. Using

internal joiners, 4’, 8’, and 12’ sections can be joined

to form longer-length luminaires. Individual 2’ and 3’

units also available, consult factory.

________

________

________

________

________

________

________________________

______________

______________

Luminaire

ENW1

# of Lamps

in Cross

Section

010005 1

020006 2

Lamp Type

32

32W T8

Nominal

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R2

2’ section(s)

R3

3’ section(s)

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

ADZT

1

Advance Mark 7 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

2

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery

pack

EN

1

Emergency battery

pack w/night light

circuit

________

________________

______________

_________________________________

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

L/LPE No lamp. Wired for energy

saving lamps.

LP830 3000K 80+ CRI

LP835 3500K 80+ CRI

LP841 4100K 80+ CRI
Reference

Lamp Chart

on website or

consult factory for other options.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

CFG Configuration

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

NYC New York City code

Notes:

1 Not available in 347V

2 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified