Wrx my98 blow-off valve adaptor instructions – Turbosmart BOV ADAPTERS - Subaru WRX MY98 User Manual
Page 4
WRX MY98 BLOW-OFF VALVE ADAPTOR INSTRUCTIONS
Head Office: Turbosmart Pty Limited, PO Box 264 Croydon, NSW, 2132 Australia
Ph: +61(2) 9798 2866
Fax: +61 (2) 9798 2826
Email:
USA Office: Turbosmart USA, 1185 Park Center Drive, Suite Q, Vista CA 92081 USA
Ph: (760) 727 7610
Fax: (760) 727 7963
Email:
PART NUMBER
FG-ADM-MY98
Step 10. Install one end of the Silicon hose assembly
supplied onto the factory boost/vacuum fitting and
secure with the 6mm spring clamp supplied.
Step 11. Install your Turbosmart BOV onto the MY98
Adaptor by following the instructions included with the
BOV. Go to Step 15 if you are installing a Plumb
back or Dual Port BOV.
Step 12. When installing either a Vee port, Supersonic
or Megasonic BOV, connect the short length of the
factory boost hose to the intercooler fitting and the long
length to the MY98 adaptor. Secure the boost hose
using the factory hose clamps.
.
Step 13. Connect the remaining end of the Silicon hose
assembly onto the BOV and secure it with the 5mm
spring clamp supplied.
Step 14. Secure the adjacent hose to the BOV using
the 250mm long cable tie supplied. This will prevent the
BOV from moving.
If you are installing either a Vee Port, Supersonic or
Megasonic BOV, your installation is complete.
Go to STEP 15 if you are installing a Plumb back or
Dual Port BOV.
Short length
Long length
Connect the long length to the Vee
Port, Supersonic or Megasonic BOV
Factory Boost Hose
Connect the short length
to the intercooler fitting
Adjacent Hose
Cable Tie