Turbosmart BOV ADAPTERS - Nissan 200SX User Manual
Page 3
200SX S14 & S15 BLOW-OFF VALVE ADAPTOR INSTRUCTIONS
Head Office: Turbosmart Pty Limited, PO Box 264 Croydon, NSW, 2132 Australia
Ph: +61(2) 9798 2866
Fax: +61 (2) 9798 2826
Email:
USA Office: Turbosmart USA, 1185 Park Center Drive, Suite Q, Vista CA 92081 USA
Ph: (760) 727 7610
Fax: (760) 727 7963
Email:
PART NUMBER
FG-ADM-200SX
Step 9. Fit the 6mm end of the reducer into the factory
vacuum/boost line and secure it with the 6mm spring
clamp supplied.
Step 10. Using an 8mm socket or screwdriver, loosen
the hose clamp on the factory plumb back hose near
the 200SX Adaptor.
Step 11. Disconnect the factory plumb back hose from
the factory BOV return pipe.
Step 12. Fit the blank-off assembly to the end of the
factory BOV return pipe. Secure the blank-off assembly
with a 40mm hose clamp supplied.
Step 13. Blank off the end of the factory plumb back
hose with the remaining 29mm blank and secure it with
the remaining 40mm hose clamp.
Step 14. Install your Turbosmart BOV onto the 200SX
Adaptor by following the instructions included with the
BOV.
Factory 6mm ID
Vacuum Line
5mm ID Silicon Hose
200SX Adaptor
Factory plumb back hose
Factory BOV return pipe
Plumb Back Hose
Factory BOV
Return Pipe
Blank-off
Assembly
Blank off the
factory plumb
back hose