5l xt forester blow-off valve adaptor instructions – Turbosmart BOV ADAPTERS - Subaru Forester 2.5 User Manual
Page 2
2.5L XT FORESTER BLOW-OFF VALVE ADAPTOR INSTRUCTIONS
Head Office: Turbosmart Pty Limited, PO Box 264 Croydon, NSW, 2132 Australia
Ph: +61(2) 9798 2866
Fax: +61 (2) 9798 2826
Email:
USA Office: Turbosmart USA, 1185 Park Center Drive, Suite Q, Vista CA 92081 USA
Ph: (760) 727 7610
Fax: (760) 727 7963
Email:
PART NUMBER
FG-ADM-FRST25
Step 5. Blank off the return hose with the 29mm
Turbosmart plug supplied. Secure the plug with the
factory hose clamp.
(If you are installing a Type III Dual Port
or a Plumb Back, do not blank off the return hose, you will be
attaching this hose to the plumb-back fitting on the BOV.)
Step 6. Install your Turbosmart BOV onto the adaptor
by following your Turbosmart BOV instructions.
Step 7. Secure the adaptor by fastening the two nuts
on either side of the adaptor flange using a 12mm ring
spanner.
Step 8. Finally, insert the factory boost/vacuum line
over your Turbosmart BOV nipple and secure with the
6mm hose spring clamp supplied.
TROUBLE SHOOTING
The following points should be checked if you find that your engine is dipping below normal idle, stalling or if the BOV is functioning poorly. Please note
the following checks will cure 99% of problems experienced with fitting your BOV.
-
Check that the O-ring on the base of the BOV is fitted correctly and is in good condition.
-
Ensure that the BOV grub screws and lock-nuts are tightened on the adaptor.
-
Ensure that the factory nuts securing the adaptor flange onto the intercooler is tightened.
-
Ensure the factory vacuum/boost line is connected to the BOV fitting and secured with the 6.35mm hose spring clamp.
-
Check the 29mm Blank is fitted on the return hose and secured with the factory hose clamp.
-
Re-adjust the setting of your BOV. Please refer to your BOV fitting instructions for further information.
Plumb-back