Electronics MC User Manual
Page 4

H:\MANUALS\IM0049C.DOC Installation Manual Model MC Shot Flow Controller
4 of 12
5. SPARE PARTS LIST
For each machine, at least one of each of the following is recommended:
a.
Spare MC Control
c.
Spare MagnaValve
6. WARRANTY
Electronics Incorporated warrants this product to be free from defect in material and workmanship for a
period of two years from date of shipment. Defective units must be returned to Electronics
Incorporated with shipping costs prepaid. Call for a Return Authorization Number and shipping
instructions. Electronics Incorporated will repair or replace defective unit at its option. No
consequential liability is assumed. No other warranty, including merchantability or fitness for purpose,
applies or is expressed or implied.
Warranty work is only available at the factory. On-site service or start-up assistance is available at
extra cost to customer. See Section VII.
Caution: Any customer attempts to modify or repair the product during the warranty period will
terminate the warranty. Standard technician labor rates will be quoted prior to repair work.
7. SERVICE/START-UP ASSISTANCE
Service is an option available at the time of original purchase or as required by customer. A purchase
order is required prior to making a service call.
8. UPGRADES - REVISIONS
Design improvements are constantly being made to our products. Please contact Electronics
Incorporated for details. When ordering spare units, please refer to model number and serial number of
each unit.
9. TROUBLESHOOTING GUIDE (WHEEL TYPE BLAST MACHINES)
1. SYMPTOM: Problems with stability
If the machine uses a variable speed drive, check it for stability or bypass it with a conventional
motor starter.
The instability may be caused by flooding/choking the wheel or trying to flow more shot than the
capability of the wheel. Check for obstructions or restrictions or unnecessary bends in the flow path.
Worn blades or damaged control cages will not pass as much shot as new blades, therefore as blades
wear the maximum shot flow rate is reduced.