Operations, Chapter 5 operations, Default operation screen – Grain Systems PNEG-1935 User Manual
Page 21

PNEG-1935 Vision Hybrid for Portable Dryers
21
5. Operations
Operations
NOTE: The following screenshots are taken from various models of portable dryers, explaining why the
picture on the screen in this manual, may be different than that of the display.
Default Operation Screen
Figure 5A
The “Operation Screen” is divided into five (5) sections.
1. Dryer Operation Animation: Located on the left side of the “Operation Screen”, the dryer operation
animation shows the status of the fans/heaters, load and unload augers and meter rolls. It will also
display the grain temperature, moisture content, moisture control setpoint and the bushel counter.
2. Dryer Status: Located at the very top of the right side of the “Operation Screen”, the dryer status will
tell the user if the dryer is stopped, started, loading or unloading.
3. Dryer Status Chart: This chart, located directly under dryer status, will show the grain temperature,
moisture in/out, temperature out and meter roll output (M.R.O) over a period of time.
4. Plenum(s): Located directly below dryer status chart, the plenum section will show temperature
setpoint, actual plenum temperature and burner status.
5. Configuration Buttons: Select from “Timers”, “Temp”, “Setup”, “View” and “M/C” buttons.
Dryer Operation
Animation
Dryer Status
Dryer Status
Charts
Plenum(s)
Configuration
Buttons