Altronix AL600ULACMCBR Installation Instructions User Manual
Page 2
- 2 -
ACMCBseries
Overview:
These units distribute and switch power to access control systems and accessories. They convert a 115VAC 60Hz input
into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an open col-
lector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button,
PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes,
Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface
enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm discon-
nect feature is individually selectable for any or all of the eight (8) outputs.
ACMCB Series Configuration Reference Chart:
AL400ULACMCB
4
3
8
Yes
1.9 amp 3.5A / 250V
AL600ULACMCB
6
6
8
Yes
1.9 amp 3.5A / 250V
AL1012ULACMCB
10
---
8
Yes
1.9 amp 3.5A / 250V
AL1024ULACMCB
---
10
8
Yes
4.4 amp
10A / 250V
Specifications:
• Power supply input options:
a) One (1) common power input for ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs (external power supply is required).
(current is determined by the power supply connected, not to exceed a maximum of 10 amp total).
• Eight (8) Access Control System trigger inputs.
Input options:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
• Eight (8) independently controlled Fail-Safe and/or Fail-Secure power outputs.
• Eight (8) auxiliary power outputs (unswitched) (PTC protected outputs are rated 2.5 amp).
• ACM8CB board main fuse is rated at 10 amp.
• Red LEDs indicate outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit..
• Alarm output relay indicates that FACP input is triggered
(form “C” contact rated @ 1 amp 28VDC not evaluated by UL).
• Green LED indicates when FACP disconnect is triggered.
• Filtered and electronically regulated outputs (built-in power supply).
• Built-in charger for sealed lead acid or gel type batteries.
• AL400ULXB, AL600ULXB and AL1012ULXB (Power Supply Board) maximum charge current .7 amp.
AL1024ULXB (Power Supply Board) maximum charge current 3.6 amp.
• Automatic switch over to stand-by battery when AC fails.
• Zero voltage drop when unit switches over to battery backup (AC failure condition).
• Thermal and short circuit protection with auto reset.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact).
Altronix
Model Number
11
5V
A
C
6
0H
z
In
pu
t
(c
ur
re
nt
d
ra
w
)
12
V
D
C
T
ot
al
O
ut
pu
t
C
ur
re
nt
(
am
p)
24
V
D
C
T
ot
al
O
ut
pu
t
C
ur
re
nt
(
am
p)
O
ut
pu
ts
C
la
ss
2
R
at
ed
Po
w
er
L
im
ite
d
A
ge
nc
y
L
is
tin
gs
U
L
L
is
tin
gs
a
nd
Fi
le
N
um
be
rs
Po
w
er
S
up
pl
y
B
oa
rd
In
pu
t F
us
e
R
at
in
g
UL File # BP6714
UL Listed for Access Control
System Units (UL 294).
“Signal Equipment”
Evaluated to
CSA Standard C22.2
No.205-M1983