beautypg.com

4 accessories and replacement parts – VEGA VEGABAR 82 Modbus and Levelmaster protocol - Operating Instructions User Manual

Page 12

background image

12

3 Product description

VEGABAR 82 • Modbus and Levelmaster protocol

46294-EN-131107

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.
Unless otherwise indicated, the packages must be stored only under

the following conditions:

Not in the open

Dry and dust free

Not exposed to corrosive media

Protected against solar radiation

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.4 Accessories and replacement parts

The display and adjustment module PLICSCOM is used for measured

value indication, adjustment and diagnosis. It can be inserted into the

sensor or the external display and adjustment unit and removed at

any time.
You can find further information in the operating instructions "Display

and adjustment module PLICSCOM" (Document-ID 27835).

The interface adapter VEGACONNECT enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, the adjustment software

PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

The adapter "DIS-ADAPT" is an accessory part for sensors with

double chamber housings. It enables the connection of VEGADIS 81

to the sensor housing via an M12 x 1 plug.
You can find further information in the supplementary instructions

"Adapter DISADAPT" (Document-ID 45250).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Screwed flanges are available in different versions according to the

following standards: DIN 2501, EN 1092-1, BS 10, ANSI B 16.5,

JIS B 2210-1984, GOST 12821-80.

Transport inspection

Storage

Storage and transport

temperature

PLICSCOM

VEGACONNECT

DIS-ADAPT

Protective cap

Flanges