Output error – M-AUDIO Lagoon User Manual
Page 23
22
Alignment error
Out of sync
Out of range
Error
Possible Reasons and Remarks
Output Error
The output error is related to the optical output of the LAGOON card. Only one
output error may appear. It is called Out of range. The out of range error may only
show up when you use ADAT Sync In or Optical In to determine the sample rate.
The audio channels were received in wrong order
(e.g. left and right channels interchanged). This error
should only appear temporarily when changing the
input data format (e.g. changing from ADAT to
S/PDIF.)
Optical input and optical output do not have the same
sample rate, i. e. your external device is not
synchronized to the LAGOON (e.g. there is a CD-
Player connected to the optical input while your
LAGOON is the clock master). Select Optical In as
Clock source in this case (General page).
1. You are using S/PDIF as output signal and the sample
rate coming in from the optical input is less than 32
kHz or higher than 96 kHz.
2. You are using ADAT as output signal and the sample
rate coming in from the optical input is below 39 kHz
or above 51 kHz.
3. The LAGOON card does not receive a valid signal at
its optical input or at the ADAT Sync In. Check your
cabling and your connected external device.