beautypg.com

VEGA VEGASON 65 Foundation Fieldbus User Manual

Page 53

background image

Electromechanical data

C

able entry

-

D

ouble chamber housing

l

1

x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5; plug M12 x 1 for

VEGADIS

61 (

optional)

or:

l

1

x closing cap ½ NPT, 1 x blind stopper

½ NPT

,

plug M12 x 1 for VEGADIS 61

(

optional)

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (

optional)

S

pring-loaded terminals for wire cross-sec-

tion up to

2.5

mm² (AWG 14)

T

ransducer cable

10)

-

L

ength

5 … 300

m (16.4 … 984.3 ft)

-

D

iameter

7.2 … 7.6

mm (0.283 … 0.299 in)

Indicating and adjustment module

V

oltage supply and data transmission

through the sensor

I

ndication

LC

display in dot matrix

A

djustment elements

4

keys

P

rotection

-

unassembled

IP

20

-

mounted into the sensor without cover

IP

40

M

aterials

-

H

ousing

ABS

-

I

nspection window

P

olyester foil

Power supply

O

perating voltage

-

N

on-Ex and Ex-d instrument

20 … 72 V DC, 20 … 253 V AC, 50/60 H

z

P

ower consumption

max. 4 VA; 2.1 W

Electrical protective measures

P

rotection

IP

66/IP 67

O

vervoltage category

III

P

rotection class

I

10)

W

ith separate version C and D.

VEGASON

65 • F

oundation Fieldbus

53

10 S

upplement

28794

-

EN