beautypg.com

10 supplement, 1 technical data – VEGA VEGASON 65 Foundation Fieldbus User Manual

Page 49

background image

10 Supplement

10.1 Technical data

General data

M

aterials, wetted parts

-

F

lange

PP

or Aluminium

-

S

wivelling holder, flange

galvanized steel

-

T

ransducer

UP

-

T

ransducer diaphragm

A

lu with PE foam rubber coating

M

aterials, non-wetted parts

-

H

ousing

A

luminium die-casting powder coated

-

S

eal between housing and housing

cover

S

ilicone

-

I

nspection window in housing cover for

indicating and adjustment module

P

olycarbonate (UL-746-C listed)

-

G

round terminal

316T

i/316L

-

transducer cable with separate version C
and D

PUR (1.1082)

W

eight

5)

-

C

ompact with flange (version A)

8 … 13.3

kg (17.6 … 29.3 lbs)

-

C

ompact with swivelling holder

(

version B)

8.7 … 10.3

kg (19.1 … 22.7 lbs)

-

S

eparate with swivelling holder

(

version C)

9.2 … 11.1

kg (20.3 … 24.5 lbs)

-

S

eparate with threaded fitting (version D)

6.5 … 7.5

kg (14.3 … 16.5 lbs)

Output variable

O

utput

-

S

ignal

digital output signal, Foundation Fieldbus protocol

-

P

hysical layer

according to IEC 61158-2

C

hannel Numbers

-

C

hannel 1

P

rimary value

-

C

hannel 2

S

econdary value 1

-

C

hannel 3

S

econdary value 2

T

ransmission rate

31.25 K

bit/s

C

urrent value

10

mA, ±0.5 mA

D

amping (63 % of the input variable)

0 … 999

s, adjustable

5)

D

epending on size and process fitting material.

VEGASON

65 • F

oundation Fieldbus

49

10 S

upplement

28794

-

EN

-081127