beautypg.com

Veris Technologies 3100 Soil EC Mapping System (1997-2008 floppy disk drive 1.76G) - Operating Instructions User Manual

Page 7

background image

Veris Technologies

Pub. #OM 1CM02-1

7



No continuity

Grounded Bolt

Coulter terminal




3) Implement Test Box – To properly measure conductivity, good electrical continuity must

be present from the coulter electrode to the instrument. The Implement Test Box (Part
No. 10759) allows you to quickly check this.

Use the following method:
a) Connect the signal cable to the terminal on the test box.
b) Touch one lead of an ohmmeter to the #1 coulter blade (left hand, standing behind

the unit) and the other lead to the #1 terminal on the test box. A reading of less than
2 ohms is normal.





Connect to coulter blade

Ohmmeter

Test Box