Issue 1.10.D

XTAccess Version 1.10– User’s Manual

Author: Serge Comes - EVS Broadcast Equipment – July 2009

44

Workflow:
1. A file is dropped in the ScanFolder (D:\myScanFolder\myFile.evs.mxf)

2. The transcoded file and its companion EVS_Metadata file is generated in

D:\CleanEdit\LowRes\

3. If the job succeeds, the source file (C:\myScanFolder\myFile.evs.mxf) is

moved to D:\CleanEdit\HighRes\

4. The two files are referenced into CleanEdit

Remarks:

To use the CleanEdit referencement : you need to install the

CEXTAccessIntegration_vxx.xx.xx.exe and configure the CLeanEdit ODBC in
general settings

If the source file has no EVS Metadata file, XTAccess will create, during the

source file move, a light EVS Metadata file for the referencing into the
CleanEdit DB