Mandown Use Change to switch the mandown-alarm on or off.
Alarm in conversation
Switch off this feature to prevent alarm activation by mistake
during an active call.
Delay
Allows you to set the amount of time the handset can remain out-
side the vertical position before a pre-alarm is triggered (1s …
75s).
Please switch
Vibra call off in the Ringer settings (see page 72) if
you wish to use the mandown alarm.
Angle
Select the inclination angle of the handset in which the alarm will
be triggered.
Steep: Approximately 45° from the vertical position.
Medium: Approximately 55° from the vertical position.
Flat: Approximately 65° from the vertical position.
The inclination angle will be detected in each axis of the handset.
No movement alarm
Use
Change to switch the no movement alarm on or off.
Alarm in conversation
Switch off this feature to prevent alarm activation by mistake
during an active call.
Delay
Allows you to set the amount of time the handset can remain still
before a pre-alarm is triggered (1 s … 75 s). To prevent unwanted
alarms, pressing any key on the device resets the delay – e.g. if you
are navigating the menu.
Sensibility
Allows you to set the sensitivity (low, medium, high). This allows
you to adapt the sensor to the different movements (e.g. ways of
walking) of the surveillance personnel:
•
Low sensibility means: Slow movements are enough to reset
the delay once again.
•
High sensibility means: Only rapid (jolting) movements will
reset the delay.
Please switch
Vibra call off in the Ringer settings (see page 72) if
you wish to use the no movement alarm.
Devices menu