You will need a dial indicator and a measurement standard.
1.
Position the standard in the center of the segment.
2.
Enter one edge of the standard.
3.
Enter the other edge of the standard.
4.
Enter the actual size of the standard, including the probe
diameter if necessary.
5.
Press
DONE
to save the segment information into the table.
The readout will automatically set the segment boundaries between the
current segment and the adjacent segments.
FIRST POINT
SECOND
POINT
8.1250
Opposite sides
FIRST POINT
SECOND
POINT
8.0000
Same side
If the calculated factor is 9999 or –9999, the machine
inaccuracy is too great and cannot be compensated.