To automatically detect the scale resolution:
•
Move the X-axis scale in a positive direction until the displayed resolution
blanks continue moving axis until a resolution value appears in the Y-axis
display field. Scale Resolution settings for each additional axis will follow and
are set in the same manner.
•
Press the
X
key to continue or, press the
S
key to save changes and
exit setup.
Entering A Scale Resolution Manually
To establish the resolution for scales without Position-Trac™, or to disable the
Position-Trac™ Power-on Position Recovery routine described on page 4, you need
to enter the scale resolution manually.
When you first enter this parameter, you will be prompted to “MOVE EACH
SCALE UNTIL RESOLUTION DETECTED”, then “X SCALE” will be displayed.
This is the X-axis scale resolution parameter.
To establish the scale resolution for non-Position-Trac™ scales:
•
Press the
Y
key to cancel the automatic resolution detection routine. “Scale
does not have Position-Trac Feature” will scroll across the X-axis display.
•
Continue to press the
Y
key to select from common resolution choices, OR
use the keypad, to enter the resolution in millimeters (Enter inches for
English resolution scales. Press the
M
key to toggle to English, then press
E
when entering these values.)
•
Press the
X
key to continue or, press the
S
key to save changes and exit
setup.
The chart below will help to determine the resolution value to enter.
Resolution on Scale Label
Metric Resolutions
10µm (.0005”)
5µm (.0002”)
2µm (.0001”)
1µm (.00005”)
.5µm (.00002”)
English Resolutions
.0005” (10µm)
.00025” (5µm)
.0001” (2µm)
Resolution value to enter
MM indicator will be lit
.01mm
.005mm
.002mm
.001mm
.0005mm
Press the MM key to toggle to English
MM indicator will “not” be lit.
.0005”
.00025”
.0001”