READOUT OPERATIONS
DRO 200E
15
R FAULT
To establish an R FAULT point:
1.
Press the
e
key then the
X
key three times. The display will read
“R FAULT”.
2.
Press the
Y
key to toggle
between the R FAULT function “OFF” or to begin entering a distance.
3.
Enter the retract fault distance as a real number (positive value). For example,
type in
2
,
.
,
5
then press the
E
key.
4.
Pressing
E
key will save the information entered and return to the
EDM/DRO view.
R FAULT, or Retract Fault, stops a cut in the event that the ram drifts above a
pre-set range from the lowest progress depth. When the R FAULT distance is
reached the retract relay is actuated for 1/10th of a second to halt the cutting cycle.