Acrocomm programming manual – Acroprint AcroComm User Manual
Page 40

AcroComm Programming Manual
6.2.25. IB
Invalid Badge Message
Format:
IB=XXXXXXXXXXXXXXXXXXXX
where
XXX… string up to 20 characters The default is “INVALID
BADGE.”
6.2.26. II
Invalid Source Message
Format:
II=XXXXXXXXXXXXXXXXXXXX
where
XXX… string up to 20 characters The default is “INVALID
SOURCE.”
6.2.27. IP
Message that will be constantly displayed on the first line of the clock’s screen
as the company’s ID,:
Format:
IP=XXXXXXXXXXXXXXXXXXXX
where XXX... string up to 20 characters.
The clock’s screen has two lines of 20 characters each. This string will be on
the first line.
6.2.28. IS
Badge Entry Sources Allowed
Format:
IS=XXXX
where X may be one or any combination of the following:
S – if the entry is through a Magnetic Stripe Reader
K – if the entry is through the keyboard
W – if the entry is through a Bar Code Reader
P – if the entry is through a Proximity Reader
6.2.29. Lx
Error Messages
Format: L0=MMMMMMMMMMMMMMMMMMMM
L1=MMMMMMMMMMMMMMMMMMMM
L2=MMMMMMMMMMMMMMMMMMMM
L3=MMMMMMMMMMMMMMMMMMMM
where
MM..: Message to be displayed if data entered is not in the validation
tables.
6.2.30. LB
Use of External Light Box
Format:
LB=X
where X can be ‘Y’ or ‘1’ for Yes, or ‘N’ or ‘2’ for No. The External Light
Box is connected to the clock to turn on a green light when a swipe is accepted
or a red light when the swipe is not accepted.
40