Command list formats, Ommand, Ormats – Acroprint AcroComm User Manual
Page 34: Acrocomm programming manual

AcroComm Programming Manual
6.2. Command List Formats
The configuration instructions format that are allowed to be sent are listed below:
6.2.1. AC
Access Table Entry
Format:
AC=FGGGGG
where
F:
1-first
record,
0-subsequent
GGG..:
Badge number, or ‘A’ to give access to all badges
An entry of AC=0 will erase the Access Table
6.2.2. AD
Access Signal Length
Format:
AD=NNN
where
NNN:
Access Signal Length in tenths of second. This is also
the signal duration when the external light box is in
use.
6.2.3. AO
Access Only Clock
Format:
AO=X
where X can be ‘Y’ or ‘1’ for Yes, or ‘N’ or ‘2’ for No. When the clock is
‘access only’ the transactions are not stored
6.2.4. AT
Update Date and Time
Format:
AT=NNN
where NNN can be the time difference between the computer and the clock in
hours.
If NNN=0 then “AT” is enough. This instruction retrieves the date and time
from the computer, adds the time difference and sends it to the clocks to
update their date and time
6.2.5. AW
Access Window
Format:
AW=HHMMHHMMDDDDDDD
where
HH:
Access window start hour
MM:
Access window start minute
HH:
Access window end hour
MM:
Access window end minute
DDDDDDD:
Days of the week the access window will be active
34