beautypg.com

Acrocomm programming manual – Acroprint AcroComm User Manual

Page 38

background image

AcroComm Programming Manual

where

NN..N: An alphanumeric field of 10 positions.

This is the facility code that is recorded on the Proximity Cards to verify their
authenticity. If a card does not match this code, it will be treated as an invalid
badge.

6.2.19. FL

Function Definition

Format:

FL=FLSPAMN

where

F:

Function Key (0-9,*,#,?)

L:

Number of Instructions the function will have (1-6)

S:

Supervisor Only function (‘Y’ or ‘N’)

P:

Check Profile Table in this function (‘Y’ or ‘N’)

A:

Check Access Table in this function (‘Y’ or ‘N’)

M:

Check Employee Messages in this function (‘Y’ or
‘N’)

N:

Transaction Printing in this function (‘Y’ or ‘N’)

6.2.20. FP

Programming Function Instructions

Format:

FP=FLMMMMMMMMMMMMMMMMSSSTDNNVT

where

F:

Function to which the instruction belongs (0-9,*,#,?)

L:

Number of instruction (1-6) according to the
function’s definition

MMM:

Message to be displayed in this instruction (16
characters)

SSS:

Data Entry Source allowed in this instruction (SKWP
or blank if data entry not allowed)

T:

Type of data to collect (1-Alphabetic, 2-Numeric, 3-
Alphanumeric, 4-Decimal)

D:

Number of decimals if the data is decimal

NN:

Maximum number of characters to receive

V:

Validation type: 0 - No validation, 1 - Press ,
2 - Use Table (T), 3 - Press and Use Table, 4
- Do not show data and use table

T:

Validation table to use. (0 - 3)

6.2.21. FS

Fingerprint Sensor

Format FS=X

Where X is ‘Y’ or ‘1’ to enable the Finger Biosensor in the FIU or ‘N’

or ‘0’ to disable it.

38