Acrocomm programming manual – Acroprint AcroComm User Manual
Page 38
AcroComm Programming Manual
where
NN..N: An alphanumeric field of 10 positions.
This is the facility code that is recorded on the Proximity Cards to verify their
authenticity. If a card does not match this code, it will be treated as an invalid
badge.
6.2.19. FL
Function Definition
Format:
FL=FLSPAMN
where
F:
Function Key (0-9,*,#,?)
L:
Number of Instructions the function will have (1-6)
S:
Supervisor Only function (‘Y’ or ‘N’)
P:
Check Profile Table in this function (‘Y’ or ‘N’)
A:
Check Access Table in this function (‘Y’ or ‘N’)
M:
Check Employee Messages in this function (‘Y’ or
‘N’)
N:
Transaction Printing in this function (‘Y’ or ‘N’)
6.2.20. FP
Programming Function Instructions
Format:
FP=FLMMMMMMMMMMMMMMMMSSSTDNNVT
where
F:
Function to which the instruction belongs (0-9,*,#,?)
L:
Number of instruction (1-6) according to the
function’s definition
MMM:
Message to be displayed in this instruction (16
characters)
SSS:
Data Entry Source allowed in this instruction (SKWP
or blank if data entry not allowed)
T:
Type of data to collect (1-Alphabetic, 2-Numeric, 3-
Alphanumeric, 4-Decimal)
D:
Number of decimals if the data is decimal
NN:
Maximum number of characters to receive
V:
Validation type: 0 - No validation, 1 - Press
2 - Use Table (T), 3 - Press
- Do not show data and use table
T:
Validation table to use. (0 - 3)
6.2.21. FS
Fingerprint Sensor
Format FS=X
Where X is ‘Y’ or ‘1’ to enable the Finger Biosensor in the FIU or ‘N’
or ‘0’ to disable it.
38