P-5 installing the extension module, Installation of the extension module, Mounting the sdi box on the monitor – MITSUBISHI ELECTRIC LDT462V User Manual
Page 26: Connection with sdi
English-22
Extension module
Option slot
Option slot
SDI BOX
P-5
Installing the extension module
Carry out as necessary
SDI for long-distance connection
or multiple-monitor connection
1. Mounting the SDI BOX on the monitor
1. Turn off the main power switch of the monitor and
disconnect the power cord.
CAUTION:
Be sure to disconnect the power cord to prevent breakdown
and electric shock.
2. Use a Phillips screwdriver to unscrew and remove the
option slot cover.
Retain the screw for later use in step 4.
3. Mount a SDI BOX (option) in the option slot of the monitor.
CAUTION:
To prevent damage, please ensure proper orientation and
position of the SDI BOX before inserting it fully into the slot.
4. Reuse the two screws removed from step 2 and properly
secure the SDI BOX.
2. Connection with SDI
There are two cases of connection.
1) Connection to one monitor
1. Connect the video device and the SDI BOX (option) using
an SDI cable (BNC) (commercially available).
NOTE:
A high-spec BNC cable capable of carrying SDI signal is called
SDI cable and distinguished from other BNC cables.
2) Connection to multiple monitors
1. After the connection made in 2-1) above, connect the
SDI OUT connector on the fi rst SDI BOX and the SDI IN
connector on the second SDI BOX using a commercially
available SDI cable (BNC).
NOTE:
The usable cable length (when SDI BOX (DP-1SDI-3G) is
mounted) is as follows:
• When one SDI BOX is connected: 100 m (3G-SDI)*
* Based on the result of the actual measurement using
the recommended cable. (Recommended cable: 1694A
made by Belden)
NOTE:
For the connection method and specifi cations of the SDI BOX,
see the catalog or operation manual of the SDI BOX.
Removal of the SDI BOX
Hold the handle on the SDI BOX for removal.
CAUTION:
Use the handle to extract the SDI BOX only. Pulling on the SDI
cable (BNC) or by other means may cause damage.
Installation of the extension module
Install the extension module to the option slot of this monitor
following the precautions and procedures described in the
manual supplied with the module.
Examples of supported extension modules:
• SDI BOX (DP-1SDI-3G)
• OPS-compliant computer (commercially available)
Recommended computer (commercially available):
ARK-DS220F-MTSA1E of Advantech Co., Ltd.
NOTE:
• Please contact module manufacturer for any compatibility
issues.
[Description]
Intel
®
OPS (Open Pluggable Specifi cation) is a standard
suggested by Intel Corporation regarding the interface between
the pluggable module mounted on monitors designed for digital
signage applications and the monitors.
Supported OPS features:
• DVI-D
• Power control
• UART
NOTE:
When an OPS-compliant module is in the option slot, the
monitor doesn’t enter the sleep mode even when POWER SAVE
in the CONFIGURATION1 menu is set to ON. Even when other
video input is selected, the monitor doesn’t enter the sleep
mode. See pages 29 and 48.