2 4-day memory sub mode, 1 how to start the pressure difference measurement – SUUNTO Advizor User Manual
Page 45
39
•
Field 3 displays the current time, to the left of the time is the text “differ”.
•
The Outer Circumference graphically displays the change in pressure where one full circle equals 100 mbars or
1 inHg.
This mode does continue in the background and allows the user to move to other modes and at the user’s convenience
return to this sub mode to view the current reading.
5.1.1 How to Start the Pressure Difference Measurement
1. PRESS the [Select] button and hold in for 2 seconds. Located in Field 1 is the text “SET”; located in Field 2, zero will
begin to flash (Fig. 47).
2. PRESS the [Mode] button to accept the flashing zero and start the difference measurement.
If the user does not desire to begin the difference measurement, PRESS either the [+] or the [-] button to toggle to the
current barometric pressure reading, then PRESS the [Mode] button to exit the setup program.
Note: If the user does not press any button for 1 minute in the setup mode, the display will automatically exit setup.
5.2 4-DAY MEMORY SUB MODE
In the Barometer mode, PRESS the [Select] button twice to enter this sub mode. This sub mode allows the user to follow
changes in pressure over the past 4 days, making weather conditions forecasting possible.
In the 4-day memory mode (Fig. 48):
•
Field 1 displays the day of the week the user is in;
•
Field 2 displays the atmospheric pressure; and
•
Field 3 displays the time and to the left the text “Memory”.
•
The Outer Circumference graphically displays the atmospheric pressure where one full circle equals 100 mbars or
1 inHg.
To view the information compiled in the 4-day memory:
PRESS the [-] button to scroll back down in increments of one hour for the first six hours, after that increments are 6 hours.
PRESS the [+] button to scroll back up.
Note: Replacing the battery will not erase this information.