York 251934-YTG-J-0910 User Manual
Page 24
251934-YTG-J-0910
24
Johnson Controls Unitary Products
115°F
125°F
5500
77
230.9
19.1
108.4
87.7
63.4
-
-
-
222.4
21.1
112.0
81.5
59.3
-
-
-
72
207.5
19.0
146.2
121.9
97.6
73.3
-
-
197.6
20.9
142.4
117.7
93.1
68.4
-
-
67
184.1
18.9
184.1
156.1
131.8
107.5
83.2
-
172.9
20.8
172.9
151.5
126.8
102.1
77.4
-
62
181.9
18.8
181.9
181.9
154.2
129.9
105.6
81.3
173.3
20.8
173.3
173.3
144.2
119.6
94.9
70.2
6000
77
232.5
19.1
124.7
92.9
67.0
-
-
-
222.3
21.1
128.9
88.9
62.6
-
-
-
72
209.0
19.0
155.1
129.1
103.1
77.1
-
-
197.5
21.0
150.8
124.5
98.2
72.0
-
-
67
185.4
18.9
185.4
165.2
139.2
113.2
87.3
-
172.7
20.8
172.7
160.1
133.8
107.6
81.3
-
62
183.3
18.9
183.3
183.3
162.8
136.9
110.9
84.9
173.2
20.8
173.2
173.2
152.3
126.0
99.7
73.4
57
181.7
18.9
181.7
181.7
163.1
137.2
111.2
85.2
173.9
20.8
173.9
173.9
154.3
128.0
101.7
75.5
6500
77
234.2
19.2
141.1
98.2
70.5
-
-
-
222.3
21.1
145.8
96.3
65.9
-
-
-
72
210.5
19.1
163.9
136.2
108.6
80.9
-
-
197.4
21.0
159.2
131.3
103.4
75.5
-
-
67
186.7
18.9
186.7
174.3
146.6
119.0
91.3
-
172.6
20.9
172.6
168.8
140.9
113.0
85.1
-
62
184.6
18.9
184.6
184.6
171.5
143.8
116.2
88.5
173.1
20.9
173.1
173.1
160.3
132.4
104.5
76.6
57
183.0
18.9
183.0
183.0
171.8
144.1
116.5
88.8
173.8
20.9
173.8
173.8
162.4
134.5
106.7
78.8
7000
77
235.9
19.2
157.4
103.4
74.1
-
-
-
222.2
21.2
162.7
103.7
69.2
-
-
-
72
212.0
19.1
172.7
143.4
114.0
84.7
-
-
197.4
21.0
167.6
138.1
108.6
79.1
-
-
67
188.1
19.0
188.1
183.4
154.0
124.7
95.3
-
172.5
20.9
172.5
172.5
147.9
118.5
89.0
-
62
185.9
19.0
185.9
185.9
180.1
150.8
121.5
92.1
173.0
20.9
173.0
173.0
168.3
138.8
109.3
79.8
57
184.3
18.9
184.3
184.3
180.5
151.1
121.8
92.4
173.8
20.9
173.8
173.8
170.6
141.1
111.6
82.1
7875
72
217.1
19.1
186.2
154.2
122.3
90.3
-
-
202.0
21.0
180.5
148.5
116.5
84.5
-
-
67
192.6
19.0
192.6
190.3
165.2
133.2
101.2
-
176.6
20.9
176.6
176.6
158.7
126.7
94.6
-
62
190.4
18.9
190.4
190.4
187.5
155.6
123.6
91.7
177.1
20.9
177.1
177.1
174.8
142.8
110.7
78.7
57
188.8
18.9
188.8
188.8
186.9
154.9
123.0
91.0
177.9
20.9
177.9
177.9
176.3
144.3
112.3
80.2
8750
72
222.3
19.1
199.7
165.1
130.5
96.0
-
-
206.7
21.0
193.5
158.9
124.4
89.8
-
-
67
197.2
19.0
197.2
197.2
176.3
141.7
107.1
-
180.6
20.9
180.6
180.6
169.4
134.9
100.3
-
62
194.9
18.9
194.9
194.9
194.9
160.4
125.8
91.2
181.2
20.9
181.2
181.2
181.2
146.7
112.1
77.6
57
193.3
18.9
193.3
193.3
193.3
158.7
124.1
89.6
182.0
20.9
182.0
182.0
182.0
147.5
112.9
78.4
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZJ210 (17.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65