Dm060 cooling capacities (5 ton), Nominal rating – York SUNLINE 2000 DM 048 User Manual
Page 11
292454-YTG-B-0507
Unitary Products Group
11
TABLE 7: DM060 COOLING CAPACITIES (5 TON)
CFM
WB °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
68
4.9
50
44
38
32
25
-
-
65
5.6
50
43
37
31
24
-
-
67
62
4.8
62
56
50
43
37
31
24
60
5.3
60
54
48
42
35
29
23
62
57
4.7
57
57
57
51
44
38
32
53
5.3
53
53
53
47
41
34
28
57
55
4.7
55
55
55
48
42
36
29
51
5.4
51
51
51
44
38
32
25
72
67
4.9
48
42
36
30
24
-
-
65
5.4
47
41
35
29
23
-
-
67
62
4.8
59
53
47
41
35
30
24
59
5.2
57
51
45
40
34
28
22
62
56
4.7
56
56
56
50
45
39
33
53
5.2
53
53
53
47
41
35
29
57
54
4.7
54
54
54
48
42
36
31
50
5.3
50
50
50
44
39
33
27
72
66
4.9
45
39
34
29
23
-
-
64
5.3
44
39
33
28
22
-
-
67
61
4.8
55
50
44
39
34
28
23
58
5.1
54
48
43
38
32
27
22
62
55
4.7
55
55
55
50
45
39
34
52
5.1
52
52
52
47
42
36
31
57
53
4.6
53
53
53
48
42
37
32
50
5.2
50
50
50
44
39
34
28
72
63
4.8
41
36
31
27
22
-
-
61
5.4
40
35
31
26
21
-
-
67
58
4.7
51
46
41
36
32
27
22
56
5.1
49
44
39
35
30
25
21
62
53
4.6
53
53
51
47
42
37
32
50
5.2
50
50
48
43
39
34
29
57
51
4.6
51
51
49
44
40
35
30
47
5.2
47
47
46
41
36
32
27
72
60
4.8
37
33
29
25
21
-
-
58
5.4
36
32
28
24
20
-
-
67
56
4.7
46
42
38
34
30
26
21
53
5.2
44
40
36
32
28
24
20
62
51
4.6
51
51
47
43
39
35
31
47
5.2
47
47
44
40
36
32
27
57
49
4.6
49
49
45
41
37
33
29
45
5.3
45
45
42
38
34
29
25
CFM
WB °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
61
6.1
48
41
35
29
22
-
-
57
6.7
46
39
33
27
20
-
-
67
55
5.9
55
52
46
39
33
27
20
50
6.6
50
50
43
37
31
24
18
62
49
5.9
49
49
49
42
36
30
23
44
6.5
44
44
44
38
31
25
19
57
47
5.9
47
47
47
40
34
28
21
42
6.5
42
42
42
36
30
23
17
72
61
6.0
45
39
33
28
22
-
-
57
6.6
43
38
32
26
20
-
-
67
54
5.9
53
49
44
38
32
26
20
50
6.5
50
47
42
36
30
24
18
62
48
5.8
48
48
48
42
37
31
25
44
6.4
44
44
44
38
32
26
20
57
46
5.8
46
46
46
40
35
29
23
42
6.4
42
42
42
36
31
25
19
72
60
6.0
42
37
32
26
21
-
-
57
6.6
41
36
30
25
20
-
-
67
54
5.8
52
47
41
36
31
25
20
50
6.5
50
45
40
34
29
24
18
62
48
5.7
48
48
48
43
37
32
27
44
6.4
44
44
44
38
33
28
22
57
46
5.8
46
46
46
41
35
30
25
42
6.3
42
42
42
37
32
26
21
72
57
6.0
38
34
29
24
19
-
-
53
6.5
37
32
27
23
18
-
-
67
51
5.8
47
42
38
33
28
24
19
46
6.4
45
41
36
31
26
22
17
62
45
5.7
45
45
44
39
34
30
25
41
6.3
41
41
39
35
30
25
21
57
43
5.8
43
43
42
37
32
28
23
39
6.3
39
39
38
33
29
24
19
72
54
6.0
34
30
26
22
18
-
-
49
6.5
33
28
24
20
16
-
-
67
48
5.8
42
38
34
30
26
22
18
43
6.4
40
36
32
28
24
20
16
62
43
5.7
43
43
39
35
31
27
23
38
6.3
38
38
35
31
27
23
19
57
41
5.8
41
41
38
34
30
26
21
37
6.2
37
37
34
30
26
22
18
NOMINAL RATING
1500
1750
85°F
POWER
INPUT
2
kW
95°F
SENSIBLE CAPACITY
1
ENTERING DRY BULB, °F
2500
2250
2000
SENSIBLE CAPACITY
1
ENTERING DRY BULB, °F
AIR ON
EVAPORATOR
COIL
TEMPERATURE OF AIR ON CONDENSER COIL
1750
POWER
INPUT
2
kW
ENTERING DRY BULB, °F
ENTERING DRY BULB, °F
AIR ON
EVAPORATOR
COIL
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
115°F
SENSIBLE CAPACITY
1
SENSIBLE CAPACITY
1
1500
TOTAL
CAP.
1
MBH
POWER
INPUT
2
kW
TOTAL
CAP.
1
MBH
TOTAL
CAP.
1
MBH
POWER
INPUT
2
kW
TOTAL
CAP.
1
MBH
2500
2250
2000
1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE
Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input
is 0.36kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor.