Table 4: cooling capacity 7-1/2 ton hp cool metric – York PREDATOR BP 090 User Manual
Page 10

259336-YTG-B-0606
10
Unitary Products Group
TABLE 4: COOLING CAPACITY 7-1/2 TON HP COOL METRIC
Return
Air
Outdoor Ambient Temperature (C) 29
Outdoor Ambient Temperature (C) 35
m
3
s
WB
(°C)
Gross
Cap.
*
(kW)
Tot.
Input
†
(kW)
Sensible Capacity (kW)
*
Return Dry Bulb (°C)
Gross
Cap.
*
(kW)
Tot.
Input
†
(kW)
Sensible Capacity (kW)
*
Return Dry Bulb (°C)
30
28
27
25
23
22
20
30
28
27
25
23
22
20
1.06
22
32
8.7
17
16
14
12
11
#N/A
#N/A
30
9.4
17
15
13
12
10
#N/A #N/A
19
29
8.4
21
20
18
16
15
13
11
27
8.9
21
19
17
16
14
12
11
17
26
8.0
25
24
22
20
19
17
15
24
8.6
24
23
21
20
18
16
15
14
28
8.0
27
25
24
22
20
19
17
25
8.5
25
24
22
20
19
17
15
1.24
22
33
8.8
19
17
15
13
11
#N/A
#N/A
31
9.5
18
16
14
12
10
#N/A #N/A
19
30
8.5
23
21
19
17
15
13
11
28
9.0
23
21
19
17
15
13
11
17
27
8.1
26
26
24
22
20
18
16
25
8.7
25
24
23
21
19
17
15
14
29
8.1
28
27
25
23
21
19
17
25
8.6
25
25
24
22
20
18
16
1.42
22
34
8.9
21
18
16
14
12
#N/A
#N/A
32
9.6
20
18
15
13
11
#N/A #N/A
19
30
8.5
25
23
21
18
16
14
11
28
9.1
25
22
20
18
15
13
11
17
28
8.2
28
27
25
23
21
18
16
26
8.8
26
26
24
22
20
18
15
14
29
8.1
29
29
27
25
22
20
18
26
8.7
26
26
25
23
21
18
16
1.53
22
34
8.9
22
20
17
14
12
#N/A
#N/A
33
9.7
21
19
16
13
11
#N/A #N/A
19
31
8.6
27
24
22
19
16
14
11
29
9.2
26
24
21
18
16
13
11
17
28
8.2
28
28
26
24
21
19
16
26
8.9
26
26
26
23
21
18
15
14
30
8.2
30
30
28
26
23
20
18
27
8.8
27
27
26
24
21
18
16
1.77
22
35
9.0
24
21
18
15
12
#N/A
#N/A
34
9.8
23
20
17
14
11
#N/A #N/A
19
32
8.6
29
26
23
20
17
14
11
30
9.3
28
25
22
19
16
13
10
17
29
8.3
29
29
28
25
22
19
16
27
8.9
27
27
27
24
21
18
15
14
31
8.2
31
31
30
27
24
21
18
27
8.9
27
27
27
24
21
19
16
Outdoor Ambient Temperature (C) 41
Outdoor Ambient Temperature (C) 46
1.06
22
30
10.1
17
15
14
12
10
#N/A
#N/A
29
10.9
17
16
14
12
11
#N/A #N/A
19
26
9.6
21
20
18
16
14
13
11
25
10.3
22
20
18
17
15
13
12
17
23
9.2
23
22
22
20
18
16
15
22
9.9
22
22
22
20
18
17
15
14
23
9.2
23
23
22
20
18
17
15
22
9.9
22
22
22
20
18
17
15
1.24
22
30
10.2
18
16
14
12
10
#N/A
#N/A
29
10.9
18
16
14
12
10
#N/A #N/A
19
26
9.7
22
20
18
17
15
13
11
25
10.3
22
20
18
16
14
12
10
17
23
9.3
23
23
22
20
18
16
14
22
9.9
22
22
22
20
18
16
14
14
24
9.2
24
23
23
21
19
17
15
22
9.9
22
22
22
20
18
16
14
1.42
22
30
10.2
19
17
15
12
10
#N/A
#N/A
29
10.9
19
16
14
12
10
#N/A #N/A
19
27
9.7
24
21
19
17
15
12
10
25
10.3
23
21
18
16
14
11
9
17
24
9.3
24
24
23
21
19
16
14
22
9.9
22
22
22
20
17
15
13
14
24
9.3
24
24
24
21
19
17
14
22
9.9
22
22
22
19
17
15
13
1.53
22
31
10.3
21
18
16
13
10
#N/A
#N/A
29
11.0
20
18
15
13
10
#N/A #N/A
19
27
9.8
25
23
20
18
15
12
10
25
10.4
24
22
20
17
14
12
9
17
24
9.4
24
24
24
21
19
16
14
22
10.0
22
22
22
20
17
14
12
14
24
9.4
24
24
24
22
19
16
14
22
9.9
22
22
22
19
17
14
12
1.77
22
32
10.4
22
19
17
14
11
#N/A
#N/A
30
11.0
22
19
16
13
10
#N/A #N/A
19
28
9.9
27
24
22
19
16
13
10
25
10.5
25
24
21
18
15
12
9
17
25
9.5
25
25
25
22
19
16
13
22
10.0
22
22
22
20
17
14
11
14
25
9.4
25
25
25
22
19
16
13
22
10.0
22
22
22
19
17
14
11
Outdoor Ambient Temperature (C) 52
1.06
22
28
11.6
18
16
15
13
11
#N/A
#N/A
19
23
11.0
22
20
19
17
15
14
12
17
20
10.5
20
20
20
20
19
17
15
14
20
10.5
20
20
20
20
18
16
15
1.24
22
28
11.6
18
16
14
12
10
#N/A
#N/A
19
23
11.0
22
20
18
16
14
12
10
17
20
10.5
20
20
20
19
17
15
13
14
20
10.5
20
20
20
19
17
15
13
1.42
22
28
11.5
18
16
14
11
9
#N/A
#N/A
19
23
11.0
22
20
18
15
13
11
8
17
20
10.5
20
20
20
18
16
14
11
14
20
10.4
20
20
20
18
15
13
11
1.53
22
28
11.6
20
17
15
12
9
#N/A
#N/A
19
23
11.0
23
22
19
16
14
11
8
17
20
10.5
20
20
20
18
15
13
10
14
20
10.5
20
20
20
17
15
12
10
1.77
22
28
11.6
22
19
16
13
10
#N/A
#N/A
19
23
11.1
23
23
20
17
14
11
9
17
20
10.6
20
20
20
17
14
11
8
14
20
10.5
20
20
20
17
14
11
8
*
These capacities are gross ratings. For net
capacity, deduct air blower motor, kW. Refer to
the appropriate Blower Performance Table for
the kW of the supply air blower motor.
†
These ratings include condenser fan motors
and the compressor motors but not the supply
air blower motor.