beautypg.com

Xantrex Technology 400R User Manual

Page 59

background image

Troubleshooting Reference

975-0162-01-01

5-5

Green
Charging
Status
light is
still flashing
and hasn’t
changed to
steady after 50
hours of
charging.

The voltage at the AC
wall outlet is less than
120 V AC.

Internal battery is
permanently damaged.

Use AC wall outlet that supplies
120 V AC.

Replace the battery.

The
compressor
runs but won’t
inflate.

The valve connector
may not be securely
placed on the valve
stem.

The item being
inflated may have a
leak.

Check that the valve connector is
securely placed on the valve stem
before closing the thumb latch.

Check that the item being inflated
has no leaks.

Check the compressor hose for any
breaks or leaks at connections.

The
compressor
runs slowly.

The compressor may
have overheated from
excessive use.

Battery voltage is too
low.

Turn off the compressor and let it
cool down.

Check the condition of the internal
battery. The battery may need to be
recharged or replaced.

Table 5-1 Troubleshooting reference

Problem

Possible Cause

Solution

This manual is related to the following products: