beautypg.com

Xantrex Technology C40 User Manual

Page 45

background image

Adjusting the C-Series Voltage Settings

975-0004-01-02 Rev D

25

The scale for the Low Voltage Disconnect setting is
calibrated as follows:

12-volt system: 10.5 to 12.5 volts
in increments of 0.2 volts,

24-volt system: 21.0 to 25.0 volts
in increments of 0.4 volts, and

48-volt system: 42.0 to 50.0 volts
in increments of 0.8 volts.

Figure 2-12 LVR and LVD Settings for Load Control Mode

12-Volt System Settings

24-Volt System Settings

14.0

12.0

13.0

L

.

V

.

R

(LOAD)

L

OW

V

OLTAGE

R

ECONNECT

12.2

12.4

12.6

12.8

13.2

13.4

13.6 13.8

12.5

10.5

11.5

10.7

10.9

11.1

11.3

11.7

11.9

12.1 12.3

L

.

V

.

D

(LOAD)

L

OW

V

OLTAGE

D

ISCONNECT

28.0

24.0

26.0

24.4

24.8

25.2

25.6

26.4

26.8

27.2 27.6

25.0

21.0

23.0

21.4

21.8

22.2

22.6

23.4

23.8

24.2 24.6

L

.

V

.

R

(LOAD)

L

OW

V

OLTAGE

R

ECONNECT

L

.

V

.

D

(LOAD)

L

OW

V

OLTAGE

D

ISCONNECT

56.0

48.0

52.0

48.8

49.6

50.4

51.2

52.8

53.6

54.4 55.2

50.0

42.0

46.0

42.8

43.6

44.4

45.2

46.8

47.6

48.4 49.2

L

.

V

.

R

(LOAD)

L

OW

V

OLTAGE

R

ECONNECT

L

.

V

.

D

(LOAD)

L

OW

V

OLTAGE

D

ISCONNECT

48-Volt System Settings (C40 only)

This manual is related to the following products: